The World's Largest Search Machine for Certified Products, Testing Equipment, and Services
141 Results
Popular:
Top Standards:

Search Intelligence

API 598API 6DASME B16.34ANSI/ASME B1...API 607ISO 5208ISO 2503API 6AAPI 6FAEN 12266-104590135180# Mfr0150300450600Score
Very High
High
Medium
Low

Bars = Total Score (manufacturers × adoption weight) • Line = # manufacturers • Click bars to search

Results for "Flame Arresters"

Products

Detonation type Flame Arresters DFA

DFA - DFA series detonation flame arresters are bidirectional fuses, tested as protection against unstable detonation conditions of explosion groups IIA and IIB1. They are dedicated to demanding installations of the petrochemical market, including aviation fuels and alcohols, as well as all installa

ISO 16852
EN 1127-1
Deflagration type Flame Arresters IFA

IFA - deflagration flame arresters of the IFA series are bidirectional fuses, tested as protection against deflagration conditions of explosion groups IIA and IIB (including groups IIA1, IIB1, IIB2 and IIB3). They are available as end devices, pipe devices with a specified maximum distance from the

ISO 16852
EN 1127-1
Pipe protection against deflagration: Concentric flame arrester

Flame arrestor tested according to DIN EN ISO 16852 as a deflagration tube arrestor Deflagration = explosion in which the flame propagates at subsonic speed. The flame arrestor prevents flame propagation to the side to be protected in the event of deflagration of explosive vapor-air or gas-air mix

ISO 16852
Breather Valves IFA+EFA
Breather Valves

IFA+EFA valves are currently the most popular model in the Petroster valve offer. They are produced in connection diameters from DN50 to DN200 and various capacity versions. This is a modern design combining a breathing valve with a flame arrester in one device, dedicated to storage and process tank

ISO 16852
EN 1127-1
EN 13463-1
+2 more
BE/HR-E-IIB3

endurance burning protection for alcohols and hydrocarbons up to explosion group IIB3 specially developed for sea going vessels but also useful for inland navigation vessels and on shore systems weather hood protects against environmental impact (i.e. weather, bird nests, etc.) weather hood opens an

ISO 16852
IMO MSC.1/Circ.1324
IMO MSC.1/Circ.677
+1 more
BE/HK-E-IIB3

endurance burning protection for alcohols and hydrocarbons up to explosion group IIB3 specially developed for inland navigation vessels and on shore systems weather hood protects against environmental impact (i.e. weather, bird nests, etc.) weather hood will open and signal the impact of a flame fus

ISO 16852
IMO MSC.1/Circ.677
IMO MSC.1/Circ.1324
+1 more
PV-VOC

Our PV-VOC series comprises high velocity pressure/vacuum valves for crude oil tankers offering the highest possible safety standards and unsurpassed operational performance. This valve provides protection against fire hazards and tank overpressure or vacuum while securing that gas emissions are kep

ISO 15364
ISO 16852
PV-ECO

Our PV-ECO series comprises high velocity pressure/vacuum valves for product- and chemical carriers offering the highest possible safety standards and unsurpassed operational performance. This valve provides protection against fire hazards and tank overpressure or vacuum while securing that gas emis

ISO 16852
ISO 15364
End fitting / end safety device: Atmospheric explosion

Flame arresters tested according to DIN EN ISO 16852 as deflagration end devices Deflagration protection Flame arrestor tested as a deflagration end device prevents flame propagation in the event of deflagration of explosive vapor-air or gas-air mixtures from the outside (atmosphere) to the insid

ISO 16852
Liquid detonation protection: foot valve

Flame arrestor tested according to DIN EN ISO 16852 as a foot valve (liquid detonation end protection). Detonation = explosion in which the flame propagates at supersonic speed. Deflagration = explosion in which the flame propagates at subsonic speed. Flame arresters tested according to DIN EN IS

ISO 16852
Liquid detonation safety device / explanation

Detonation: An explosion in which the flame propagates at supersonic speed. Deflagration = explosion in which the flame propagates at subsonic speed. If explosive gas ignites in a container or pipe, a deflagration (explosion) is triggered. When a flame front travels through a pipe, the flame speed

ISO 16852
BE/HK-E-IIB

endurance burning protection for alcohols and hydrocarbons with MESG ≥ 0,5mm. weather hood protects the PROTEGO<® flame arrester unit against environmental impact, such as nesting animals and weather conditions in case of fire, the weather hood opens, allowing the flame to be seen from a far distan

ISO 16852
DR/ES

minimum number of FLAMEFILTER® discs due to the effective shock absorber quick removal and installation of the complete PROTEGO® flame arrester unit and FLAMEFILTER® discs in the cage due to modular design the FLAMEFILTER® discs can be individually replaced the right angle design saves pipe elbows e

ISO 16852
FA-CN-IIA, IIB3

design available for elevated operating temperatures and pressures compact design with easy access cover easy maintenance without disassembling of the pipeline modular flame arrester unit enables individual FLAMEFILTER® to be replaced and cleaned bi-directional flame transmission proof design provid

ISO 16852
FA-CN-IIA1

state of the art design for bio-, sewage- and landfill gas applications design available for elevated operating temperatures and pressures compact design with easy access cover easy maintenance without disassembling of the pipeline modular flame arrester unit enables individual FLAMEFILTER® to be re

ISO 16852
FA-CN-IIA1

state of the art design for bio-, sewage- and landfill gas applications design available for elevated operating temperatures and pressures compact design with easy access cover easy maintenance without disassembling of the pipeline modular flame arrester unit enables individual FLAMEFILTER® to be re

ISO 16852
DR/ES, DN 1/4 - 3/4

compact design minimum number of FLAMEFILTER® discs due to shock absorber technology and optimal geometry Design for IIB3: the device can be serviced without disconnecting the pipe the individual FLAMEFILTER® can be quickly removed and installed provides protection from deflagration and stable de

ISO 16852
Liquid detonation protection: End protection

Flame arrestor tested according to DIN EN ISO 16852 as a liquid detonation end-of-line device. Detonation = explosion in which the flame propagates at supersonic speed. Deflagration = explosion in which the flame propagates at subsonic speed. The flame arrestor prevents flame propagation during d

ISO 16852
Skip to the end of the images gallery Base Model Image Shown  Skip to the beginning of the images gallery Model 7B00

The Model 7B00 detonation flame arrestor is a device that can be fitted to the opening of an enclosure or to the connecting pipe work of a system of enclosures. Its primary function is to allow the flow of gases or vapor of flammable liquids through the enclosure, but prevent the transmission of a f

ISO 16852
Model 7A00

The Model 7A00 detonation flame arrestor is a device that can be fitted to the opening of an enclosure or to the connecting pipe work of a system of enclosures. Its primary function is to allow the flow of gases or vapor of flammable liquids through the enclosure, but prevent the transmission of a f

ISO 16852
Model 6A00-HT

The Model 6A00 inline deflagration flame arrestor is a device that can be fitted to the opening of an enclosure or to the connecting pipe work of a system of enclosures. Its primary function is to allow the flow of gases or vapor of flammable liquids through the enclosure, but prevent the transmissi

ISO 16852
Skip to the end of the images gallery Base Model Image Shown  Skip to the beginning of the images gallery Model 6A00-EM

The Model 6A00 inline deflagration flame arrestor is a device that can be fitted to the opening of an enclosure or to the connecting pipe work of a system of enclosures. Its primary function is to allow the flow of gases or vapor of flammable liquids through the enclosure, but prevent the transmissi

ISO 16852
Model 6A00

The Model 6A00 inline deflagration flame arrestor is a device that can be fitted to the opening of an enclosure or to the connecting pipe work of a system of enclosures. Its primary function is to allow the flow of gases or vapor of flammable liquids through the enclosure, but prevent the transmissi

ISO 16852
Pressure/vacuum valve tested as a deflagration end-of-life protection device

Pressure/vacuum valve and deflagration end-of-life protection
 Pressure/vacuum valve tested as a flame arrestor according to DIN EN ISO 16852. Ventilation lines on storage tanks prevent negative and positive pressure during filling, emptying, cleaning, heating, cooling or inerting of the container

ISO 16852
Trunnion-Mounted Ball Valves

Tight shutoff is essential during oil and gas applications, and the superior anchoring of FET’s PBV trunnion-mounted ball valves makes them especially well-suited for large, high-pressure valve applications. The trunnion-mounted stems absorb line pressure and minimize friction between balls and seat

ISO 15848-1
API 6D
API 598
+7 more
Page 1 of 6 (141 total items)

Standard

Manufacturers in Results

VAHN-TECH International Inc.SCV Valve, LLCPROTEGO®Flammer GmbHOliver Valves Limited
Atılım Makine İmalat San. ve Tic. Ltd. Şti.Pekos Valves, S.L.U.FBV Inc.Valland S.p.A.JC ValvesPetroster Sp. j.
Neco Valves S.r.l. Brand (Nssl Italia)Fukuzawa Valve Co., Ltd.GWC InternationalArfluErreesse S.r.l.

Standards in Results (10)

API 598

168

API 6D

156

ASME B16.34

124

ANSI/ASME B16.34

76

API 607

61

ISO 5208

51

ISO 2503

45

API 6A

42

API 6FA

38

EN 12266-1

35

We value your privacy. TEKEN44 uses cookies and collects personal data to connect manufacturers, labs, publishers, and clients, improve your experience, and comply with legal requirements. By clicking "Accept", you agree to our Privacy Policy and Terms of Use.