Bars = Total Score (manufacturers × adoption weight) • Line = # manufacturers • Click bars to search
Results for "Pressure Measurement"
No direct product was found, please contact to connect your products
Products

The EMCO Orifice Plate is used as a primary element in flow measurement of liquid, gas and steam applications based on the differential pressure principle. According to this working principle, the orifice plate creates a flow restriction in the pipeline to allow measurement of the resulting pressure

The EMCO Meter Run is used as a primary element in flow measurement of liquid, gas and steam applications based on the differential pressure principle. According to this working principle, the orifice plate creates a flow restriction within the meter run to allow measurement of the resulting pressur

The EMCO Orifice Plate is used as a primary element in flow measurement of liquid, gas and steam applications based on the differential pressure principle. According to this working principle, the orifice plate creates a flow restriction in the pipeline to allow measurement of the resulting pressure

The venturi tube is a method of measuring fluid flow using a cylindrical depressurizer with a constriction. As a fluid flows through the tube, its flow rate increases due to the restriction. The pressure difference between upstream and downstream is proportional to the flow rate.

The EMCO Orifice Plate is used as a primary element in flow measurement of liquid, gas and steam applications based on the differential pressure principle. According to this working principle, the orifice plate creates a flow restriction in the pipeline to allow measurement of the resulting pressure

The ISA 1932 Nozzle is used as primary elements in flow measurement of steam, liquid and gas according to the differential pressure principal and in accordance with ISO 5167-3. In the ISO 5167-3 standard the geometry and method of use are specified for nozzles to determine the flow rate of the flowi

Tanaka’s new Automatic Pour / Cloud / Freezing Point Tester mpc-6 is designed with “Simple, Reliable, and Robust” concepts. The mpc-6 requires a mere 4.5 mL sample and provides quick automatic determination of 3 key cold property measurements with high precision. INNOVATIVE Tanaka’s original mini t

aap-6 automatically determines aniline point for wide range of samples. The use of special infrared detector gives the instrument it's ability to see through dark / opaque samples such as power generation fuels and marine diesel oils. The measuring cell can be easily removed and placed on an analy

It’s been over 50 years since we started manufacturing automated distillation testers. Nowadays, we deliver to customers in more than 70 countries. ad-7 automatically performs distillation test of petroleum products as well as narrow boiling range samples. 10.4 inch LCD with tough panel has been ad

asp-6 automates softening point test of bitumen and other materials by utilizing photo-electric device with a wide light beam, which assures reliable detection. Stirring function has been newly applied and a test can be done with one of the four test modes; Water, Glycerin, Water+Stirring, Glycerin

This patented and robust viscometer quickly and precisely measures the dynamic viscosity of predominantly Newtonian fluids in the measuring range of 1 to 10,000 mPas. This differs from Ubbelohde viscometers, which measure kinematic viscosity.

Easy Operation Equipped with 7-inch color LCD touch screen for simple, intuitive operation. Simply select a pre-registered test mode. No need to set detailed parameters. Ignition Source Can be switched between gas and electric ignition. Safety device When flame is detected by the thermal fuse or det

afp-300 automatically executes the Cold Filter Plugging Point (CFPP) test prescribed in ASTM D6371 and other test methods. The new user interface has greatly enhanced the usability. The built-in CFC-free Sterling cooler accommodates both linear and stepwise cooling.

Since 1966, Tanaka has been delivering automated flash point testers for higher productivity at petroleum laboratories. The theme of the 8th generation model series is “ Ergonomic, Versatile, Robust and Safe “ ●Ergonomic: Color coordinated display and switches for high visibility / intuitive operat

Since 1966, Tanaka has been delivering automated flash point testers for higher productivity at petroleum laboratories. The theme of the 8th generation model series is “ Ergonomic, Versatile, Robust and Safe “ ●Ergonomic: Color coordinated display and switches for high visibility / intuitive operat

Extended Measurement Range With an external chiller, a measuring range down to 0 ℃ can be achieved. Easy Operation Equipped with a 7-inch color LCD touch screen for simple, intuitive operation. Simply select a pre-registered test mode. No need to set detailed parameters. Data Storage 1,000 test resu

The i-Fischer® DIST D-2892/5236 CC / FISCHER® AUTODEST® The 800/860 AC combines two proven distillation methods in one fully automated system: atmospheric-vacuum-based TBP distillation (ASTM D2892) and pot still distillation of heavy residues (ASTM D5236). Both processes can be carried out independ

The i-Fischer® DIST D-2892 CC / FISCHER® AUTODEST® 800 AC is a turnkey, computer-controlled system for TBP distillations according to ASTM D2892. All process steps—from debutanization to vacuum distillation—are performed fully automatically. No manual operator intervention is required. With a separ

The i-Fischer® Dist D-2892 MC – 10 ltr is an automatic distillation system in accordance with ASTM D2892 (TBP) for the precise fractionation of crude oils. Equipped with computer-aided control, the system automatically controls the entire distillation process – including fraction change and temperat

The i-Fischer® Dist D-1160 CC is a fully automatic, computer-controlled system for boiling point and distillation analysis according to ASTM D1160. Designed for the analysis of petroleum products, vegetable oils, and blends, the system operates under both atmospheric pressure and vacuum—quickly, saf

The EMCO Orifice Plate is used as a primary element in flow measurement of liquid, gas and steam applications according to the differential pressure principle. According to this working principle, the orifice plate creates a flow restriction in the pipeline to allow measurement of the resulting pres

The EMCO wet gas meter is used to measure the flow rate in natural gasses with a certain level of liquid present. Based on the classical venturi tube according to ISO 5167-4 with single pressure tappings. A third tapping may be applied for liquid flow rate determination using the pressure loss ratio

The ORIMAS & STEEMCO-MAS flow meters measure the mass flow of most gasses, liquids and steam. With a compact design, they combine the measurement of velocity, static pressure and temperature into one unit. The electronics computerise the mass flow by using the 3 measured values. The mass flow mete
Standard
Standards in Results (10)
ANSI/ASME MFC-3M
ASTM D4052
ISO 12185
ISO 5167-2
ASTM D5002
ASTM D5191
ASTM D6378
EN 13016-2
EN 140
ASTM D323