The World's Largest Search Machine for Certified Products, Testing Equipment, and Services
14 Results
Popular:
Top Standards:

Search Intelligence

ANSI/ASME MF...ISO 5167-2ISO 5167-1ISO 5167-4ISO/TR 15377VDI/VDE 2041ISA RP3.2AGA XQ1201 (...DIN 19205-1ANSI ASME B1...036912# Mfr036912Score
Very High
High
Medium
Low

Bars = Total Score (manufacturers × adoption weight) • Line = # manufacturers • Click bars to search

Results for "Mass Flow Measurement For Liquids & Gases"

Products

ORIMAS & STEEMCO-MAS Mass Flow Meter for Insertion Between Flanges

The ORIMAS & STEEMCO-MAS flow meters measure the mass flow of most gasses, liquids and steam. With a compact design, they combine the measurement of velocity, static pressure and temperature into one unit. The electronics computerise the mass flow by using the 3 measured values. The mass flow mete

ISO 5167-1
ISO 5167-2
ANSI/ASME MFC-3M
Venturi tube flow meter - Flow measurement with primary element

The venturi tube is a method of measuring fluid flow using a cylindrical depressurizer with a constriction. As a fluid flows through the tube, its flow rate increases due to the restriction. The pressure difference between upstream and downstream is proportional to the flow rate.

ISO 5167-1
ISO 5167-4
ANSI/ASME MFC-3M
EMCO Meter Run Series MSRS and MSRF with Carrier Rings and Corner Pressure Tappings

The EMCO Meter Run is used as a primary element in flow measurement of liquid, gas and steam applications based on the differential pressure principle. According to this working principle, the orifice plate creates a flow restriction within the meter run to allow measurement of the resulting pressur

ISO 5167-1
ISO 5167-2
ISO 5167-3
+4 more
Orifice Plates

Orifice plates are on of the most economical devices of measuring flow. SEIKO´s production range extends from standard size orifice plates, through orifice carrier and flange assemblies to customized meter runs. Typical orifice plate are supplied with a data tab welded to the plate. The majority of

ISO 5167-1
API MPMS 14.3.2/AGA Report No. 3, Part 2
FLEMCO Flow Meter for Insertion Between Flanges

The FLEMCO flow meter is a compact orifice meter used as a primary element in flow measurement of liquid and gas according to the differential pressure principle. With its volumetric flow measurement, this meter is suitable for application within process industries, pharmaceuticals and the power ind

ISO 5167-2
ANSI/ASME MFC-3M
EMCO Orifice Plate Series ISB/1 for RF Flanges

The EMCO Orifice Plate is used as a primary element in flow measurement of liquid, gas and steam applications according to the differential pressure principle. According to this working principle, the orifice plate creates a flow restriction in the pipeline to allow measurement of the resulting pres

ISO 5167-2
ANSI/ASME MFC-3M
ISA RP3.2
+1 more
EMCO Orifice Plate Series MRK with Carrier Rings and Corner Pressure Tappings for Insertion Between Flanges

The EMCO Orifice Plate is used as a primary element in flow measurement of liquid, gas and steam applications based on the differential pressure principle. According to this working principle, the orifice plate creates a flow restriction in the pipeline to allow measurement of the resulting pressure

ISO 5167-2
ANSI/ASME MFC-3M
DIN 19205-1
EMCO Orifice Plate Series MEF/2 with Single Pressure Tapping for Insertion between RTJ Flanges

The EMCO Orifice Plate is used as a primary element in flow measurement of liquid, gas and steam applications based on the differential pressure principle. According to this working principle, the orifice plate creates a flow restriction in the pipeline to allow measurement of the resulting pressure

ISO 5167-2
ANSI/ASME MFC-3M
ANSI ASME B16.5
Flow Conditioner

Flow straighteners and conditioners are used in conjunction with flowmeters. They can smooth out turbulent and transitional flows and help meters measure more accurately. Location sould be between 7,5D and 12D from meter device. Flow can be straighten by Plate Conditioner or Tube Bundles. They ca

ISO 5167-2
EMCO Orifice Plate Series MES with Single Pressure Tapping in All Welded Construction

The EMCO Orifice Plate is used as a primary element in flow measurement of liquid, gas and steam applications based on the differential pressure principle. According to this working principle, the orifice plate creates a flow restriction in the pipeline to allow measurement of the resulting pressure

ISO 5167-2
ANSI/ASME MFC-3M
EMCO Wet Gas Meter Type WG-V

The EMCO wet gas meter is used to measure the flow rate in natural gasses with a certain level of liquid present. Based on the classical venturi tube according to ISO 5167-4 with single pressure tappings. A third tapping may be applied for liquid flow rate determination using the pressure loss ratio

ISO 5167-4
ISO/TR 15377
ANSI/ASME MFC-3M
+1 more
EMCO Classical Venturi Tube Type KVR (Machined)

The classical venturi tube is one of the most tested and trusted flow meters on the market. Based on the ISO 5167-4 standard, it offers durable flow measurement with minimal pressure loss.

ISO 5167-4
ANSI/ASME MFC-3M

Manufacturers in Results

Fuji Electric France
TCR Tecora

Standards in Results (10)

ANSI/ASME MFC-3M

11

ISO 5167-2

9

ISO 5167-1

7

ISO 5167-4

5

ISO/TR 15377

3

VDI/VDE 2041

2

ISA RP3.2

1

AGA XQ1201 (Report No.3)

1

DIN 19205-1

1

ANSI ASME B16.5

1

Relevant Standard Groups (1)

View all relevant groups

We value your privacy. TEKEN44 uses cookies and collects personal data to connect manufacturers, labs, publishers, and clients, improve your experience, and comply with legal requirements. By clicking "Accept", you agree to our Privacy Policy and Terms of Use.