The World's Largest Search Machine for Certified Products, Testing Equipment, and Services
10 Results
Popular:
Top Standards:

Search Intelligence

EN 779ISO 16890-4EN 13053ASHRAE 52.2ISO 16890-2ISO 16890-3ISO 16890-1VDI 6022 Bla...ANSI/UL 900ISO 5011036912# Mfr036912Score
Very High
High
Medium
Low

Bars = Total Score (manufacturers × adoption weight) • Line = # manufacturers • Click bars to search

Results for "Bag filters"

Products

Cam-Flo
Bag filters

The Cam-Flo product page mentions several standards and certifications, including ISO 16890, EN 779, EN 13053, EN 15805, ISO 29461-1:2021, ISO 9001:2015, ASHRAE 52.2:2017, EC 1935:2004, ISO 846, VDI 6022, and UL 900.

ISO 16890-4
EN 779
EN 13053
+2 more
VENTUS Compact
Air handling and air conditioning units

VENTUS Compact TOP are energy saving units equipped with a hexagonal counter-flow recuperator, EC motors, Mini-Pleat or bag filters and integrated controls in the Plug&Play standard. Capacity: from 1250 m3/h to 4000 m3/h Energy recovery: up to 90% recovery efficiency Foundation: standing AHUs with

ISO 12100
ISO 12100-1
ISO 13857
+1 more
Hi-Flo
Bag filters

The Hi-Flo product page mentions several standards and certifications, including ISO 16890, EN 779, EN 13053, EN 15805, ISO 846, VDI 6022, and EC 1935:2004.

ISO 16890-4
EN 779
EN 13053
+1 more
S-Flo
Bag filters

The S-Flo product page mentions the following standards and certifications: - ISO 16890 - EN 779 - ASHRAE MERV 10 - ASHRAE MERV 11 - ASHRAE MERV 13 - ASHRAE MERV 14 - UL 900

ISO 16890-4
EN 779
ANSI/UL 900
Streamline® Containment Isolator - Class III
Containment Isolator - Class III

The Streamline® Containment Isolator Class III (SCI Class III) configuration solely operates in a negative pressure, with its on-board fan providing -37 Pa to -125 Pa (max) in the process chamber and -25 Pa to -75 Pa (max) in the pass-through chamber. "To comply fully with biosafety standards, the

ISO 10648-2
ANSI/IEST/ISO 14644-1
FIRE FIGHTING SCBA

The Rescue hood is a constant flow hood, used in case of emergency to help people in need. It is extremely easy to use and can be worn by anybody regardless their face shape and size. The Rescue hood can be used with every SPASCIANI respirator connected to the second air outlet. The hood is rapidly

EN 137
EN 148-1
Sanitary Clamps

The biopharmaceutical industry has made a strong move towards single-use technology, so Nordson MEDICAL has developed PharmaLok™ sanitary clamps to simplify the assembly process by making it effortless to securely attach sanitary fittings to bag ports and filters. PharmaLok™ clamps are ASME BPE comp

ANSI/AAMI/ISO 10993-1
Dräger PARAT® 3160

The Dräger PARAT® 3160 is a half mask escape device equipped with a multi-gas ABEK15 filter. Approved to the only recognized standard for filtering industrial escape devices (DIN 58647-7), it provides users a minimum of 15 minutes escape time. Compared to PARAT® 3100, the half mask and filter are va

DIN 58647-7
Respiratory Protection Catastrophe-Set STANDARD

1 full face mask C 701 (class 3) olive/black 1 special- multi-type combined filter DIRIN 500 A2B2-P3R D NBC 1 preformed carrying and storage bag for full face mask

Manufacturers Media

Manufacturers in Results

Topas GmbHFiltration Engineering & Consultants (FEC)CamfilSKC Inc.
Nordson MEDICAL
VTS GroupSpascianiEKASTU Safety GmbHTara FiltersBoll & Kirch Filterbau GmbH (BOLLFILTER)TAISEI KOGYO Co., Ltd.Douglas Chero S.p.A.
Maxitrol Company

Standards in Results (10)

EN 779

10

ISO 16890-4

5

EN 13053

3

ASHRAE 52.2

3

ISO 16890-2

3

ISO 16890-3

3

ISO 16890-1

2

VDI 6022 Blatt 1

2

ANSI/UL 900

2

ISO 5011

2

We value your privacy. TEKEN44 uses cookies and collects personal data to connect manufacturers, labs, publishers, and clients, improve your experience, and comply with legal requirements. By clicking "Accept", you agree to our Privacy Policy and Terms of Use.