Results for "Walls"

Products

Fire Rated Walls – 1 Hour Fire Rated Wall Panels for Maximum Protection

Panel Built’s fire rated walls provide superior fire resistance, ensuring workplace safety and code compliance. Our 1 hour fire rated wall panels are laboratory-tested and ASTM-certified, offering reliable protection for warehouses, military facilities, and commercial buildings. 🔺 1 Hour Fire Rate

ASTM E119
ANSI/ASTM E119
Barrier Walls

Walls serving as protective barriers in various settings.

Acoustic Walls

Walls that reduce noise pollution in urban areas.

Retaining Walls

Walls designed to hold back soil and prevent erosion.

Armored Ground Walls

Walls reinforced to withstand heavy loads and environmental conditions.

WALL THICKNESS - PRODUCTION RANGE

4 - 26 mm DIAMETER - PRODUCTION RANGE 219,1 - 3300 mm

API 5L
ISO 3183
AWWA C200
+5 more
EFS Static Fire Damper 3 hr rating

EFS Multi-Blade fire damper is rated as a 3 hours fire damper for use in static systems, per SI 1001 part 3 (UL 555). As a life safety fire damper, it has a failsafe design which enables the damper to automatically close upon the detection of heat and/or loss of power. The electric heat responsi

NFPA 80
NFPA 90A
NFPA 92
+4 more
EFS Static Fire Damper 1.5 hr rating

EFS Multi-Blade fire damper is rated as a 1-1/2 hour fire damper for use in static systems, per SI 1001 part 3 (UL 555). As a life safety fire damper, it has a failsafe design which enables the damper to automatically close upon the detection of heat and/or loss of power. The electric heat respo

NFPA 80
NFPA 90A
NFPA 92
+4 more
EFS Dynamic Fire Damper 3 hr rating

EFS Multi-Blade fire damper is rated as a 3 hours fire damper for use in dynamic systems, per SI 1001 part 3 (UL 555). As a life safety fire damper, it has a failsafe design which enables the damper to automatically close upon the detection of heat and/or loss of power. The electric heat respons

NFPA 80
NFPA 90A
NFPA 92
+4 more
TYPES OF PIPE FOR CONSOLIDATION AND TUNNELING
CONSOLIDATION AND TUNNELING

Designed to withstand static and dynamic loads, Alessio pipes guarantee high performance even in the presence of strong ground stresses. They are suitable for various intervention techniques, such as direct drilling , injection of cement mixtures or drainage installations . Thanks to protective tr

EN 10219-1
ASTM A252/A252M
EN 10240
+2 more
POLYSAFE 5L Safety Box & Incineration Container

POLYNOR is the sole supplier of POLYSAFE® 5LSafety Box & Incineration Container which is standardized and approved by the US Military and NATO under NSN 6530-01-460-4782. Polysafe 5L Safety Box and Incineration Container for safe and easy collection and destruction of used syringes. POLYNOR is the

PQS/E010/SB01.1
PQS/E003/FZ03-VP.1
ISO 23907-1
+2 more
Wall type Indicator Post

Meet or Exceed the Requirements of NFPA 24 Standard. Indicates the State of the Valve OPEN or SHUT Position. Target Nut to allow 13 to 45 Turns. Protected Windows. Telescoping Operating Rod. Easily Adjustable Indicator OPEN and SHUT Targets. Spray Painted Interior and Exterior meet or exceed all app

ANSI/NFPA 24
NFPA 24
ANSI/AWWA C550
+2 more
AMDW Series Double Wall Grease Duct

Double Wall Grease duct is ideal for use in kitchen ventilation applications where reduced clearance or zero-inch clearance to combustibles is needed. Grease duct is ETL listed to mastandard UL-1978 and UL Standard 2221 and rated for continuous operation at 500° F and intermittent operation at 2000°

ANSI/UL 1978
UL 2221
ANSI/ASTM E814
+2 more
Krah Pipes

Krah Pipes are made from HD-PE100 (acc. to DIN16961, EN13476, ASTM F894, ISO9969 and other intl. standards) are produced with an integrated electro fusion joint socket and spigot. The pipe is completely helically extruded with profiles or solid wall, tailor made for any kind of application within th

DIN 16961-1
EN 13476-1
ANSI/ASTM F894
+2 more
2" C509 MJ

The Clow Resilient Wedge Valve, with its unique features and benefits, was the first to be manufactured with both AWWA and UL/FM approval for all water system requirements. Clow Valve Co was the first to introduce, and still leads in the design and technical development, of the bubble-tight resilien

ANSI/AWWA C509
AWWA C515
ANSI/AWWA C550
+2 more
UL / FM / AWWA Large Diameter Resilient Seated Gate Valves Mechanical Joint x Mechanical Joint (14”-24”)

UL / FM / AWWA Large Diameter Resilient Seated Gate Valves – Mechanical Joint x Mechanical Joint Ends. 14”-16”-18” Sizes are UL / FM at 250 psi rating. 20” and 24” are UL / FM at 200 psi rating. Manufactured to AWWA C515-15 Standard. Mechanical Joint Ends are to AWWA C111 / AWWA C153 Standard. Stain

AWWA C515
AWWA C111
AWWA C153
+2 more
American Spiralweld Pipe
AMERICAN Spiralweld Pipe

Spiral-welded steel pipe for the municipal water and wastewater transmission markets, industrial, hydroelectric and power markets including large diameter fabrication for treatment plants and pump stations.

ASTM A252/A252M
ANSI/AWWA C200
ASTM A139/A139M
+1 more
FireMaster Egress Fire Curtain

A vertical deploying curtain barrier developed to allow occupants to egress to safety, suitable for openings in walls, lobbies, and lift openings in commercial buildings.

ANSI/UL 10D
UL 10D
UL 1784
+1 more
Direct Fired Heater (Process heater)
Direct Fired Heater

Depending on the type of process, duty, space and customer requirements, a furnace type is designed. Aitesa designs the following types of furnaces: Horizontal cylindrical kiln: Up to 1 Gcal/h. It has a horizontal combustion chamber without tubes and 1 burner located at the bottom of the horizonta

API 560
API 535
API 530
+1 more
Single-Wall Pipe

The use of single-wall plastic drainage pipe is only recommended where drainage water is free of debris and floating material. Its primary use is to collect and convey drainage water by open gravity. The plastic drainage pipe is manufactured to the highest quality control standards only using high-

ASTM F405
ASTM F667/F667M
AASHTO M252
+1 more
HDPE Solid-Wall Pipes

High-density polyethylene pipes suitable for various applications, including water transmission, gas distribution, and wastewater collection.

ISO 4427-2
ISO 4427-1
EN 1555-1
+1 more
Vista Single Wall

or customers who prefer to get the supplies from the front of the fume hood, right beneath the work surface, in favor of optimal utilization of the work space

SII 1839
EN 14175-1
EN 14175-2
+1 more
Page 1 of 6 (141 total items)

Manufacturers Media

Standard

Manufacturers in Results

Werner & Weber GmbHDuraventNema Enclosures Manufacturing of Texas, LLCPOLIMATAdvanced Drainage Systems
Advanced Drainage Systems, Inc.Blain Hydraulics GmbHMekisan Asansör ve Çelik Konstrüksiyon Sanayi Ltd. Şti.AMERICAN Cast Iron Pipe CompanyAdvanced Drainage Systems, Inc. (ADS)ELKOPLAST CZ, s.r.o.MolecorWisconsin Tubing, LLC
Polynor AS
CGM s.r.l.

Standards in Results (10)

AASHTO M252

15

AASHTO M294

15

EN 81-20

11

EN 81-50

11

ASTM F2306/F2306M

11

EN 13476-1

11

ASTM A252/A252M

10

DIN 30722-1

9

EN 10219-1

8

EN 12201-1

8

Labs in Results (1)