The World's Largest Search Machine for Certified Products, Testing Equipment, and Services
17 Results
Popular:
Top Standards:

Search Intelligence

ASHRAE 52.2ISO 21501-4ISO 14644-1ISO 11171EN 1822-1ANSI/IEST/IS...EN 13181MIL STD-E-50...MIL STD-E-85...MIL STD-810D...02468# Mfr02468Score
Very High
High
Medium
Low

Bars = Total Score (manufacturers × adoption weight) • Line = # manufacturers • Click bars to search

Results for "Particle Size Analyzers "

Products

Portable Particle Counters
Cleanroom Particle Counters

Engineered for you, they provide real-time cleanroom particle counting in an easy-to-use, reliable instrument that's ready for measurement. Built-in global regulatory guidance and international standards, such as ISO 14644-1:2015, ISO 21501-4:2018, EU GMP Annex 1 (2008 and 2022), and China GMP, make

ANSI/IEST/ISO 14644-1
ISO 21501-4
HEPA Box Clean room air filtration terminal devices for particulate control

TANGRA HEPA Box is designed for final air filtration in ventilation and air conditioning systems with installation of HEPA filters, class H13 and H14 (EN 1822-1:2019).

ISO 29463-1
ISO 29463-2
VDI 6022 Blatt 1
+6 more
GloveFAST Cyto Pharma

The GloveFAST Cyto Pharma isolator complies with the following standards and certifications: - **DIN 12980:2017-05**: Specifies requirements for isolators used in pharmaceutical applications. - **DIN EN ISO 14644-7**: Pertains to cleanrooms and associated controlled environments, focusing on isola

EN 61010-2-101
ISO 14644-1
EN 1822-1
+3 more
GloveFAST Cyto

The FASTER GloveFAST Cyto is a space-saving, high-performance negative pressure isolator with a 4-stage HEPA filter system, specially developed for the safe handling of highly effective substances such as cytostatics and other toxic or mutagenic agents. Despite its compact design, the isolator offer

ISO 14644-1
EN 1822-1
EN 12469-2
+1 more
GloveFAST Aseptic

The GloveFAST Aseptic is a modern, GMP-compliant positive pressure isolator with vertical laminar airflow that has been specially developed for work processes where maximum product safety, sterility and operator protection are essential. Thanks to its modular design, the isolator can be flexibly ada

EN 1822-1
EN 12469-2
EN 61010-1
+1 more
GloveFAST Clean

The GloveFAST Clean isolators are designed to meet specific standards and certifications. They utilize three low-pressure drop H14 HEPA/ULPA filters with an efficiency exceeding 99.995% MPPS, as per EN 1822. The operational conditions ensure air cleanliness in Class ISO 3, in accordance with ISO 146

EN 1822-1
ISO 14644-1
Remote Particle Counters
Cleanroom Particle Counters

Their small size, flexible power options and wireless capabilities allow installation where space is limited. Worry-free monitoring with best-in-class data buffering reduces risk of data loss during network outages. Only the AeroTrak™+ Remote Particle Counters are backed by an industry exclusive 5 y

ISO 21501-4
BioTrak Real-Time Viable Particle Counter
Cleanroom Particle Counters

The only accepted method to replace active and passive air sampling in Grade A. This biofluorescent particle counter provides real-time counts of total and viable particles in pharmaceutical manufacturing environments to reduce aseptic interventions, improve root-cause investigations, and increase p

ISO 21501-4
Models 8301-AQM1 and 8301-AQM2

The Particles Plus® 8301-AQM1 and 8301-AQM2 Series portable particle counter and environmental monitor measures particles from 0.3 to 25 µm in mass concentration and stores indoor air quality measurements of temperature, relative humidity, CO2, and TVOC in the 8301-AQM2. This instrument is the most

ISO 21501-4
Model 2301

The 2301 particle counter provides a particle size measurement range of 0.3 or 0.5 to 25.0 μm at a flow rate of 0.1 CFM (2.83 LPM). These sensors enable efficient particle counting with specifications that exceed ISO 21501-4 and JIS B9921 calibration standards. These sensors have 4 fixed-size parti

ISO 21501-4
PAMAS 4132

The PAMAS 4132 is used as a particle counting system for Single & Multipass Filter test rigs. The standard system fits in the test rigs of filter manufacturers. In case of a Single Pass Filter Test, the liquid passes the filter only once and then is deviated to the outflow. For ß-ratio-analyses, th

ISO 11171
ISO 4402
ISO 19438
+2 more
PAMAS OLS50P

The PAMAS OLS50P online particle counter is a stationary instrument for fluid condition monitoring. All types of light extinction sensors of the PAMAS HCB-LD series can be integrated in the PAMAS OLS50P. If required, the sensor can be built of resistant material, so that it can be used for the analy

ISO 11171
ISO 4402
ISO 21501-3
+4 more
PAMAS AS3

The PAMAS AS3 Autosampler is a fully automated laboratory particle counter for the unattended measurement of up to 600 samples per day.

ISO 11171
ISO 4406
SAE AS4059
+2 more
PAMAS OLS4031

The online particle counter PAMAS OLS4031 emerged from the standard particle counter PAMAS S4031. The standard shell is made of coated steel. For Phosphat-Ester applications, the PAMAS OLS4031 is manufactured with a special stainless steel shell that protects the housing from corrosive liquids. The

ISO 11171
ISO 4402
GJB 420A
+8 more
PAMAS FastPatch 2 GO

The microscope system PAMAS FastPatch 2 GO has been developed to comply with the standard ISO 4407 as an automated filter membrane particle counting and sizing system. The system is designed to measure the particles trapped on the surface of the filter. The analysis uses advanced image analysis and

ISO 4406
SAE AS4059
NAS 1638
+3 more
Suspension Polyvinyl Chloride Resin
Distribution of plastic materials

Suspension Polyvinyl Chloride Resin has always been the most historical well-known product of Industrie Generali, having been direct producer for more than 25 years. We trade PVC/S of the main European producers, in the traditional ranges K58 – K65 – K67 – K70, for extrusion, moulding and blow-mould

ISO 60
ISO 13320
ISO 1628-2
PAMAS FSA-2002

The PAMAS FSA-2002 Floc Size Analyser has been designed for coagulation and water treating systems. Water is often treated by adding flocculents. These flocculation agents are used to gather solid undissolved contaminants to particulate agglomerates. Before the process of filtration commences, the f

ISO 21501-3

Manufacturers Media

Manufacturers in Results

PAMAS Partikelmess- und Analysesysteme GmbHTopas GmbHFASTER S.r.l.Particle Technology
Filtration Engineering & Consultants (FEC)
eralytics GmbHAnton Paar Ltd.HORIBA, Ltd.TANGRA – AV Ltd.Industrie Generali S.p.A.

Standards in Results (10)

ASHRAE 52.2

6

ISO 21501-4

6

ISO 14644-1

6

ISO 11171

5

EN 1822-1

5

ANSI/IEST/ISO 14644-1

4

EN 13181

3

MIL STD-E-5007

3

MIL STD-E-8593A

3

MIL STD-810D/E Sand (RTCA/DO-160E/F Sand

3

Labs in Results (1)

Relevant Standard Groups (1)

View all relevant groups

We value your privacy. TEKEN44 uses cookies and collects personal data to connect manufacturers, labs, publishers, and clients, improve your experience, and comply with legal requirements. By clicking "Accept", you agree to our Privacy Policy and Terms of Use.