The EMCO Orifice Plate is used as a primary element in flow measurement of liquid, gas and steam applications according to the differential pressure principle. According to this working principle, the orifice plate creates a flow restriction in the pipeline to allow measurement of the resulting pres

The ISA 1932 Nozzle is used for high velocity, non-viscous, erosive flows which would wear or damage an orifice plate. Typically nozzles have a larg capacity and well accuracy with high velocity flows.The required straight inlet section is much less than an orifice and the discharge coefficient of t

The ISA 1932 Nozzle is used as primary elements in flow measurement of steam, liquid and gas according to the differential pressure principal and in accordance with ISO 5167-3. In the ISO 5167-3 standard the geometry and method of use are specified for nozzles to determine the flow rate of the flowi

The new generation JBF-M features a more robust structural design and fully meets all latest market design standards and requirements. It is engineered to perform reliably under extreme conditions, including high temperatures, cryogenic environments, and highly abrasive applications—making it the id

AD syringe 2ml | Vaccine Capacity (Ml): 2.00 | Graduations (Ml): 0.10 | Syringe Material(S): Polypropylene | Packaging & Sterility Assurance: Yes | Other Needle Size Options: Yes | Auto-Disabling At:: End of injection | Needle Size: Other | Needle Size (Other): 21Gx1.5" (0.80x38mm) | Ad Sub Category

The FAR-2xx8 series is designed to provide clearer and more accurate Radar images of the surroundings, while increasing reliability and decreasing overall cost of ownership with easy maintenance. Signals are safely transported though the Ethernet network between the antenna and below deck processin
The MA120 is a 200 Amp AC/DC mini clamp meter with built-in AC voltage detector and built in LED flashlight. The meter measures Frequency up to 1 kHz with 0.01Hz resolution, auto ranges with auto power off and data hold functions. Complete with a year warranty, 2 AAA batteries and soft case.

Full Bore (Full Port) Pressure: Class 150, DIN PN16, DIN PN40 Temperature: Down to -196°C Cavity Relief Hole Investment casting body and cap Long neck design Blow-out proof stem Viton O-Ring on stem Anti-static design Locking device design Direct mounting pad ISO 5211

The Clow Resilient Wedge Valve, with its unique features and benefits, was the first to be manufactured with both AWWA and UL/FM approval for all water system requirements. Clow Valve Co was the first to introduce, and still leads in the design and technical development, of the bubble-tight resilien

High molecular crosslinked polyethylene (PEX) with minimum bending radius of 6× the diameter at 68°F (20°C). Maximum operating temperature 180°F @ 100 psi (82°C @ 7 bar). Red printing for identification of hot water lines. The PureLink® Plus PEX-a tubing may be used with fittings that are compliant

Building service, campus submetering, municipal distribution networks- Spire meets your resource management needs with reliable ultrasonic flow measurement. Battery powered, the SpiRely and 280W-CI2 are the low cost, high performance choice for water flow monitoring throughout your system. Readily a

ISO 19880-3 (Hydrogen gas – Refuelling stations – Part 3: Valves) distinguishes between valves for maintenance (Class B) and for operation (Class A). While Class B valves are designed to withstand only 100 cycles of operation at ambient temperature, Class A valves must withstand 102,000 cycles (100,

Resilient seated gate valve with electric actuator flanged with monolithic ISO top flange and full bore gate valve. Body bonnet and wedge made of ductile cast iron EN-GJS 400-15, NBR/EPDM fully vulcanised wedge. Epoxy coating minimum 250 microns according to EN ISO 12944-5, GSK RAL certificate. Wedg

The new generation of oil-injected rotary screw compressors from Kaeser’s CSD series now delivers performance with even greater precision and efficiency. The integrated package consisting of motor, timing gears and airend permits the most energy-efficient airend speed to be selected for each operati

MrPEX® POTABLE PEX-a Tubing is Cross-Linked Polyethylene (PEX-a) manufactured in accordance with ASTM F 876. Tubing is listed to ASTM F 876/F877/F2023, ASTM E84 (CSA B137.5), cNSFus-pw, NSF/ANSI-61, NSF/ANSI-14, Annex G, NSF U.P.Code PEX 5106, ICC-PMG, ANSI/AWWA 904. MrPEX® POTABLE PEX-a tubing is r

The Safeprotex 1.2m x 1.2m Fiberglass Fire Blanket is the ideal solution for small-scale kitchen fires, widely applicable in home kitchens, small commercial kitchens, workplace kitchens, and workshops. Designed for fast and safe fire suppression, this fire blanket is perfect for extinguishing small

FEATURE Full port, 1/2″~12″ (DN15~DN300) W.P. : PN16 / 40 W.T. : -20°C~200°C (-4°F~392°F) Investment casting Blow-out proof stem Anti-static device (option) ISO 5211 Mounting pad Flange dimension : DIN 2501 Face to face : DIN 3202 Part 1 – F4 / F5

Full port, 1/4″~4″ (DN8~DN100) W.P. : 1/4″~1″ – 2000 WOG (PN150) 1-1/4″~2″ – 1500 WOG (PN100) 2-1/2″~4″ – 1000 WOG (PN63) W.T. : -20°C~200°C (4°F~392°F) Investment casting Blowout proof stem Antistatic device (option) Locking device Tapped & drilled mounting pad (option) TALuft approved (option)

This garment is not intended as protection from Hydrocarbon Flash Fires, Electric Arc Hazards, or welding sparks 0.35mm FR-treated PVC/polyester/PVC material 2″ Yellow prism reflective tape Generous sizing for comfort and freedom of movement Micro welded seams for durability and waterproofness 100%

The AMERICAN Series 2500 Ductile Iron 250 psig AWWA Resilient Wedge Gate Valve is designed for use in drinking water, sewage and fire protection systems as well as irrigation and backflow control systems. The Series 2500 Resilient Wedge Gate Valve is furnished in configurations that are UL Listed an

D.P.I. has a wide range of dust, gas and combined filters: series 200 (to be used in pairs), series 230 and DIRIN (with threaded connector EN 148/1). The series 200 include particulate, gas and combined filters in a synthetic resin container built with special screw in connector for use with half ma