The World's Largest Search Machine for Certified Products, Testing Equipment, and Services
35 Results
Popular:
Top Standards:

Search Intelligence

ISO 5832-3ISO 5832-4ASTM F136ISO 5834-2ISO 5832-1ISO 13779-2ASTM F75ISO 5832-2ASTM F138EN 35806121824# Mfr0255075100Score
Very High
High
Medium
Low

Bars = Total Score (manufacturers × adoption weight) • Line = # manufacturers • Click bars to search

Results for "HIP SYSTEMS"

Products

ECOFIT® hip stem

The ECOFIT® total hip system includes a complete variety of cementless and cemented hip stems for primary arthroplasty. Both standard offset stems and lateralised offset stems are available in cementless fixation or cemented options. The choice of the implant material for any given mode of fixation

ISO 5832-4
ISO 5832-3
ISO 13779-2
EMR Revision Hip System

In revision arthroplasty, especially in cases of osteolysis or large cement mantels, the extended femoral defects can cause intraoperatively shaft fractures when removing the stem. The defects and fractures must be bridged by a long stem. The implants have to be adapted exactly to the diameter of th

ISO 5832-3
ASTM F136
Ball head

The placement of the head on the stem gives an articulated partial prosthesis. The head is set on the taper of the stem giving required movement within the inner semisphere of the acetabulum. Acetabular implants for endoprosthetics made from modern high-performance materials have proven themsel

ISO 5832-1
ISO 5832-2
ASTM F75
+3 more
AGILON® Trauma prosthesis

The AGILON® modular shoulder system offers the surgeon great flexibility via an extensive range of modular components and has been designed for reconstruction following 3-fragment to 4-fragment fracture of the humeral head as well as arthritic scenarios. It is possible to change from the anatomic re

ISO 5832-3
ISO 5832-4
ISO 5832-2
+2 more
The SCR Revision Stem

With our further developed cementless SCS/SCL/SCR stem system with long-range anchorage, we offer an implant that has proven itself over many years. This stem system is available in a lateral and standard version and also as a revision stem. The long-proven double cone shape ensures high rotational

ISO 5832-11
ASTM F1295
ISO 5832-3
+2 more
Stainless Steel Medical Wires, Bars and Profiles

Raajratna is now introducing wide range of high quality wires, bars & profiles for medical sectors. We are supplying material for implants, needles and instruments. We can provide optimum quality wire in 302, 303, 304, 304V, 316, 316L, 316LVM, 316LRM, 420, 17-4PH, 420B grades and tempers. We delive

ASTM F138
ASTM F136
ISO 5832-1
+2 more
AGILON® Omarthrosis

The AGILON® modular shoulder system offers the surgeon great flexibility via an extensive range of modular components and has been designed for arthritic scenarios as well as reconstruction following 3-fragment to 4-fragment fracture of the humeral head. It is possible to change from the anatomic re

ISO 13779-2
ISO 5832-3
ISO 5832-2
+2 more
Quadrofit Total Knee System

The Quadrofit Total Knee System is designed and developed for use in cemented and cementless application of Total Knee arthroplasty. The unique femoral cutting guide combines various functionalities in one component. This enables the surgeon to shape the femur fast and accurate with only one guide p

ASTM F75
ISO 5832-4
ASTM F136
+1 more
Modular Straight Cementless / Cemented Stem

The Modular Straight Cementless and Cemented Stem hip prostheses are designed to be used as primary and revision total hips. The stem sizes allow accurate matching of prosthesis to the medullary canal. The prosthesis offers dual fixation by combining the locking effect of a stem to bone contact, plu

ASTM F136
ISO 5832-3
ASTM F75
+1 more
Bipolar Head

Placement of cup together with a femoral head on stem gives an articulated partial prosthesis. The modular outher shell is manufactured from certified stainless steel and inner side, the insert is manufactured from Ultra High Molecular Weight Polyetylene UHMWPE.

ISO 5832-1
ASTM F138
ASTM F75
+1 more
Energy Pro Evo
Ppe- Personal fall Protection Equipment for your safety

The further development of the proven Energy Pro – the mast riser harness. It is designed for all users who place high demands on a belt. Our ENERGY PRO EVO is used for climbing lattice, wooden, catenary masts and for steel and industrial installations. It is now also used on fall arrest systems. E

EN 358
EN 361
EN 813
Energy Pro Plus
Ppe- Personal fall Protection Equipment for your safety

The tried-and-tested classic version of the Masteiger harness with additional Safe-Click buckle in the leg area. It is used for climbing lattice, wood, catenary masts and for steel and industrial installations. It is now also used on fall arrest systems. It is for all users who have high demands. E

EN 358
EN 361
EN 813
FIXED-BEARING POSTERO-STABILIZED HIFIT

The product page for the FIXED-BEARING POSTERO-STABILIZED HIFIT mentions the following standards: - NF ISO 5832-4 - NF ISO 5834-2 - NF ISO 5832-3 These standards pertain to the materials used in the femoral component, tibial insert, and tibial baseplate, respectively.

ISO 5832-4
ISO 5834-2
ISO 5832-3
UNICOMPARTIMENTAL HERMES

The product page for UNICOMPARTIMENTAL HERMES mentions the following standard numbers: - NF ISO 5832-4 - NF ISO 5834-2 - NF ISO 5832-3 These standards pertain to the materials used in the femoral component, tibial insert, and tibial baseplate, respectively.

ISO 5832-4
ISO 5834-2
ISO 5832-3
REVISION HERMES POSTERO-STABILIZED

The product page for the REVISION HERMES POSTERO-STABILIZED mentions the following standards: - NF ISO 5832-4 - NF ISO 5834-2 - NF ISO 5832-3 These standards pertain to the materials used in the femoral component, tibial insert, and tibial baseplate, respectively.

ISO 5832-4
ISO 5834-2
ISO 5832-3
Almond Modular Cementless / Cemented Stem

The Almond Modular Cementless Stem and Almond Modular Cemented Stem are well proven implants. They consist of a complete set for primary total hip replacements: The femoral stems are designed to guarantee an optimal metaphyseal filling. The metaphyseal zone has a triangular section to avoid the g

ASTM F136
ISO 5832-3
ISO 5832-4
AIDA® short stem

The AIDA® short stem is designed to provide metaphyseal-only cementless anchorage within the spongiosa of the proximal femur. It is proximally supported at the calcar as well as laterally via the distal tip. Axial and rotational stability also arise from the tapered and trapezoidal cross-sectional g

ISO 5832-3
ISO 13779-2
ECOFIT® short stem

In addition to the primary hip stems the ECOFIT® hip system also offers the option of a short stem system. Both standard offset short stems and lateralised offset short stems are available as a cementless fixation option. The modular instrument platform provides the flexibility to intraoperatively

ISO 5832-3
ISO 13779-2
Quadrofit Revision Knee System

Quadrofit Revision Knee System is indicated for cases of revision of a primary total knee replacement or for primary total knee replacement when bone augmentation is required. Primary total knee arthroplasty may be subject to failure for various reasons, including polyethylene wear, aseptic loosenin

ASTM F75
ISO 5832-4
EcoFit® cup

In order to minimise the micro movement that can cause polyethylene (PE) wear at the metal shell - PE liner interface, a special locking mechanism has been developed. This allows the use of a BIOLOX® delta ceramic insert or a PE insert with the same cup design. The PE inserts are sterilised with eth

ISO 5832-3
ISO 13779-2
Optifit Cementless Cup

In principal for all forms of arthrosis, advance wear and tear of the hip joint because of degeneratif, posttraumatic or rheumatoid arthritis fracture of avascular necrosis of the head of femur. Sequelae of earlier operations such as osteosynthesis, joint reconstruction, arthrodesis, hemiarthroplast

ISO 5832-3
ASTM F136
PATELLOFEMORAL HERMES

The product page for PATELLOFEMORAL HERMES mentions the following standards: - NF ISO 5832-4 - NF ISO 5834-2

ISO 5832-4
ISO 5834-2
ic-bipolar head

The implantcast range of ic-bipolar heads has been designed for use in hemiarthroplasty procedures - especially for femoral neck fractures. The outer shell of the bipolar component is highly polished and acts as a bearing surface which articulates directly with the native acetabulum. All sizes are p

ISO 5832-4
ISO 5834-2
The Straight Stem

The straight stem is a hip endoprosthesis for cemented anchorage that has proven itself over decades. It is made of a CoCrMo cast alloy (ISO 5832-4) or implant steel (ISO 5832-9). The fine groove structure enables good cement adhesion. Inward and outward deflection countersinks ensure easy handling

ISO 5832-4
ISO 5832-9
Page 1 of 2 (35 total items)

Manufacturers Media

Manufacturers in Results

Euromed Implants GmbH
CeraverIntraumaStemcup Medical Products AGPlus Orthopedics India Private Limited
Raajratna Metal Industries LimitedDecon7 Systems
NRG SystemsCaptiveAire Systems, Inc.Orenco Systems, Inc.TopAir SystemsSevic Systems SEEndor Systems 2009 LtdMrPEX® Systems

Standards in Results (10)

ISO 5832-3

21

ISO 5832-4

16

ASTM F136

9

ISO 5834-2

7

ISO 5832-1

7

ISO 13779-2

6

ASTM F75

5

ISO 5832-2

3

ASTM F138

3

EN 358

2

We value your privacy. TEKEN44 uses cookies and collects personal data to connect manufacturers, labs, publishers, and clients, improve your experience, and comply with legal requirements. By clicking "Accept", you agree to our Privacy Policy and Terms of Use.