
Bars = Total Score (manufacturers × adoption weight) • Line = # manufacturers • Click bars to search
Results for "ANSI/NFPA 1970"
Products

NFPA : 1970 – 2025 protective footwear for structural fire fighting CSA Z195-14 / ASTM F3413-24 Grade 1 Steel toe and plate CSA Omega – Electric shock resistant 18kV Chemical resistant tested as per EN 13832-1:2006 14″ tall Snug Fit design and ergonomic orthotic insole Flame retardant rubber upper w

NFPA : 1970 – 2025 protective footwear for structural fire fighting NFPA : 1990 – 2022 liquid splash-protective against hazardous material emergencies CSA Z195-14 / ASTM F3413-24 Grade 1 Steel toe and plate CSA Z195-14 “Green Fir Tree” chainsaw protection – Chainsaw Protection (Highest Class 3 (28m/

60-90 minute fire rated doors with temperature-rise tested to NFPA 252/UL 10B/UL 10C up to 10 ft. tall. Available with full-vision glazing, standard and narrow profiles, multiple hardware options and finishes including custom aluminum clad or stainless steel clad. See below for more information!

20-45 minute fire rated doors tested to NFPA 252/UL 10B/UL 10C up to 10 ft. tall. Available with full-vision glazing, standard and narrow profiles, multiple hardware options and finishes including custom aluminum clad and stainless steel clad. See below for more information!

The IMI Orton MV Series triple eccentric metal seated valve ensures leak-tight performance in high-pressure, high-temperature, and cryogenic applications. Featuring a precision-engineered triple-offset design, it eliminates sealing surface friction, enhancing durability and reliability. With bi-dire

AMI-SIL® AS and CAS hot work fabrics are made from a minimum 96% pure amorphous silica cloth and are rated to 1800°F (980°C). The following AMI-SIL AS and CAS hot work fabrics have been tested and rated to the ANSI/FM 4950 Standard which is now required by the NFPA 51B. AS1800G & AS3600 meet USCG1

Trunnion mounted ball valves, construction to ASME B16.34 - API6D, 2/3 piece bolted body, split body, side entry, double block & bleed, flanged RF/RTJ to ANSI B16.5, face to face to ANSI B16.10, full/ reduced bore, ISO (5211) top work standardized for actuation, seat leakage rate to ISO 5208 Rate A,

The IMI C-REX™ double eccentric segmented ball valve delivers reliable, high-cycle performance in severe service applications. Designed for bi-directional tight shutoff, it features a cavity-free, torque-seated design that enhances durability and minimises wear. Available in sizes from DN 12 to 900

2-piece Body Full Port Chrome-Plated Ball Virgin PTFE Seats Adjustable Packing Nut Blow-Out Proof Stem MSS-SP-110 500 psig (1-¼”, 2″) for UL use CSA B125.14 (¼” – 2”) CSA ½, 5 & 125 psi (½” – 2″) CSA ½ & 5 psi (2½” & 3″) 29 in-Hg rating for Vacuum Service UL approved (½” – 2”) FM approved (½” – 2″)

Design Standards: 1) API 600 (ISO-10434)/API 6D/ASME B16.34 2) BS 1873/ASME B 16.34 3) BS 1868/API6D/ASME B16.34 Size Range: 1) Gate Valve:- ANSI Class 900 : 1/2" to 36" ANSI Class 1500 : 1/2" to 24" ANSI Class 2500 : 1/2" to 24" 2)Globe Valve :- bbANSI Class 900 : 1/2" to 24" ANSI C

Single and Double-Wall Positive Pressure Special Gas Vent engineered for venting today’s high efficiency natural gas-burning or propane fired appliances, categories II, III and IV as defined by the Standard for Gas-Fired Central Furnaces, ANSI Z21.47 and NFPA 54.

Floating ball valves, construction to ASME B16.34 – ASME VIII Div.II, 2 piece bolted body, split body,side entry, flanged RF/RTJ to ANSI B16.5, face to face to ANSIB16.10, full/reduced bore, ISO (5211) top work standardized for actuation, metal seated (ball & seats with Tungsten or Chromium Carbides

Single and Double-Wall Pressure Industrial Chimney for Heating Appliances, Boiler Breeching, Generator and Fume Exhaust and other applications as defined by standard NFPA 211.

Reduces a higher inlet pressure to lower outlet pressure. Provides a consistent outlet pressure over a wide flow range. Pilot operated main valve is not subject to pressure fall-off. Outlet pressure is adjustable with a single screw. Can be maintained without removal from the pipeline. Flanged Ends

Reduces a higher inlet pressure to lower outlet pressure. Provides a consistent outlet pressure over a wide flow range. Pilot operated main valve is not subject to pressure fall-off. Outlet pressure is adjustable with a single screw. Can be maintained without removal from the pipeline. Flanged Ends

Meet or Exceed the Requirements of NFPA 24 Standard. Indicates the State of the Valve OPEN or SHUT Position. Target Nut to allow 13 to 45 Turns. Protected Windows. Telescoping Operating Rod. Easily Adjustable Indicator OPEN and SHUT Targets. Spray Painted Interior and Exterior meet or exceed all app

Trunnion mounted ball valves, construction to ASME B16.34-API6D, 2/3 piece bolted body, split body,side entry, double block & bleed, flanged RF/RTJ to ANSI B16.5, face to face to ANSI B16.10, full/ reduced bore, ISO (5211) top work standardized for actuation, seat leakage rate to ISO 5208 Rate A, f

Dry Pipe Valves for use as an automatic means of controlling water flow to automatic dry-pipe sprinkler systems. Vertical orientation. Peroxide cured EPDM with Fabric Diaphragm. NFPA 13 Standard. Latched Clapper Type. Air Supervisory Pressure Switches included. Rated Working Pressure 5 – 300 psi. CE
Standard
Standards in Results (10)
ASME B16.34
API 6D
API 607
API 6FA
ANSI/AWWA C550
AWWA C550
EN 593
API 600
ANSI Z21.80
ANSI Z21.80/CSA 6.22





