Olfasense
Olfasense is an internationally leading specialist odour consultancy assisting industry to assess and solve environmental odour problems and to evaluate commercial products using sensory and molecular analysis techniques. They are also world leaders in the supply of odour measurement technology and olfactometers.
All Products(6)

Corrosive gas test chamber SK400C
With the SK400C corrosive gas test chamber, we have successfully integrated this corrosive gas dosing system into a CTS climatic chamber to ensure standardised climate simulation and thus enable reproducible induction of corrosion. Its refrigeration technology is designed entirely with CO₂ compressors, making it particularly environmentally friendly and compliant with the latest version of the F-Gas Regulation. With its outstanding performance and a test volume of 400 litres on up to 3 levels, the SK400C corrosive gas test chamber allows you to efficiently scale up your corrosion tests, making it one of the highest quality corrosive gas test chambers on the market.

Corrosive gas test chamber SK1500C
With the SK1500C corrosive gas test chamber, we have successfully integrated this corrosive gas dosing system into a CTS climatic chamber to ensure standardised climate simulation and thus enable reproducible induction of corrosion. Its refrigeration technology is designed entirely with CO₂ compressors, making it particularly environmentally friendly and compliant with the latest version of the F-Gas Regulation. With outstanding performance and a test volume of 1500 litres on up to 3 levels, the SK1500C corrosive gas test chamber is not only one of the largest, but also one of the highest quality corrosive gas test chambers on the market, allowing you to efficiently scale your corrosive gas measurements.

VOC test chamber EK1000
The quality of indoor air in vehicles is strongly influenced by volatile organic compounds (VOCs) released from components, semi-finished products and materials used in the vehicle interior. The Olfasense 1 m³ VOC emission test chamber EK1000 allows characterization of the emissions of volatile organic compounds under precise test conditions, and is fully compliant with the requirements of ISO 12219-4 and VDA 276. The chamber meets also all requirements of the manufacturer standardards GS97014-3 (BMW method), PN 780 (Porsche method), VCS 1027, 2769 (Volvo method), as well as PV 3942 (Volkswagen method). The chamber is optionally available with a SHED function for testing according to GS-97014-2, as well as a fogging device according to VDA 276 and VCS 1027, 2769 (Volvo method). The chamber has been developed as a joint venture with the company CTS, one of the leading specialists in the field of environmental simulation. Their innovative and technically high-quality products are delivered to the most renowned industrial companies worldwide, with more than 12,000 devices sold in Germany and abroad. Major client segments include the automotive industry and its suppliers, as well as test laboratories. By consolidating their respective know-how and expertise, our two companies have developed the EK1000 VOC emission test chamber, providing clients a technically and economically optimized test system to characterize emissions of volatile organic compounds under precise test conditions.
View Product
CSD30 odour sampling device
The CSD30 is a sampling device for collecting odour samples in gas sampling bags, with a default odour sampling duration of 30 minutes. The CSD30 odour sampling device is available with different sample volumes: 10 l, 30 l, 60 l. Using the lung principle, the sample flows into the gas sampling bag through the sampling tube only, without passing through pumps or other equipment. The materials used for ‘wetted’ parts that are in contact with the sample flow are PTFE and stainless steel, in compliance with EN 13725. The sample flow is regulated using a calibrated nozzle that’s integrated in the sampling device. Other nozzles, flows and filling times are available on request. The odour sampling rate is independent of the static pressure conditions at the sampling point if the pressure difference is less than 150 mbar. The sampling flow is closed automatically once the gas sampling bag is full. Alternatively, you can select a shorter sampling duration using a countdown timer. The CSD30 odour sampling device operates from its integrated rechargeable NiCd battery, so it does not require an AC power connection. The device is also robust and easy to operate.

TO9 evolution olfactometer
The TO9 evolution olfactometer has all the functionality of the TO8 evolution olfactometer, plus the dual-forced choice method. The maximum dilution increases to 217 allowing you to measure samples of higher odour concentrations than is possible with the TO8 evolution olfactometer. Just as the TO8 evolution, this olfactometer can be used equally as a home-based laboratory, as well as a mobile on-site laboratory to keep sample storage time to a minimum, to increase flexibility, and to offer quicker reporting. The provided WiNose evolution LIMS ensures the best quality at all odour measurement sites, by supporting you in fulfilling essential quality management and quality control procedures in your day-to-day lab operation and audit preparation. The TO9 evolution olfactometer is available as 4-station or 6-station olfactometer and meets all requirements of EN 13725:2022.

TO8 evolution olfactometer
The TO8 evolution olfactometer combines the latest scientific and technological advances with decades of practical experience – enabling us to set new benchmarks in the field of olfactometry. The compact size and transportability of this olfactometer model mean you can use it equally as a home-based laboratory, as well as a mobile on-site laboratory to keep sample storage time to a minimum, increase flexibility, and offer quicker reporting. The TO8 evolution olfactometer allows for easy setup and is simple to maintain. You can be assured of the reliability of our well-known robust equipment, manufactured in-house in Germany. The heart of the TO8 evolution olfactometer is the ultra-modern and purpose-designed dilution system, which is based on the proven principle of combining gas jet pumps and fixed sapphire orifices. The olfactometer software package provides an olfactometer control software to support your laboratory in delivering odour measurements at the highest quality; as well as a state-of-the-art Laboratory Information Management System (LIMS) which has been specifically designed to meet the needs of odour laboratories. The new WiNose LIMS supports odour laboratories in fulfilling quality management procedures and in increasing efficiency in day-to-day lab operation by managing equipment, samples, measurement results, and panel data in a central location. The TO8 evolution olfactometer is available as 4-station or 6-station olfactometer and meets all requirements of EN 13725:2022.