Standart Pompa ve Makina Sanayi Tic. A.Ş.
Standart Pompa is Turkey's first 100% domestic pump producer, founded in 1957. The company specializes in manufacturing high-quality, durable, and environmentally friendly pump groups, fire extinguishing systems, and booster pumps for various sectors including industry, building technologies, water management, and petro-chemistry.
All Products(3)

SDS UL/FM
Design Features According to UL & FM All interior bolt or screw that are exposed to pumped liquid shall be of rolled bronze or corrosion resistant material The pump shall be provided with automatic air-release valve, circulation relief valve and pressure gauges Bearings shall have an L-10 rating of not less than 5000 hours at maximum load. The pumps shall be provided with at least four packing rings plus a lantern ring. The lantern ring may be permitted to replace one ring of packing. Impellers, wear rings, shafts, lantern rings, glands shall be made of corrosion resistant material. Following material specifications are applied to STANDART UL/FM fire pumps

SNK UL/FM
Design Features According to UL & FM All interior bolt or screw that are exposed to pumped liquid shall be of rolled bronze or corrosion resistant material The pump shall be provided with automatic air-release valve, circulation relief valve and pressure gauges Bearings shall have an L-10 rating of not less than 5000 hours at maximum load. The pumps shall be provided with at least four packing rings plus a lantern ring. The lantern ring may be permitted to replace one ring of packing. Impellers, wear rings, shafts, lantern rings, glands shall be made of corrosion resistant material. Following material specifications are applied to STANDART UL/FM fire pumps:

NFPA 20
Fire Pump Group Control System Individual control panels are used for electric pump, diesel pump and jockey pump Lock mechanism are used on panels Continuous grounding Pumps can run by manual control and emergency-run mechanical control on controller By the help of Locked Rotor Protection (LRP), in case of locking rotor main switch is automatically shut down. No thermic protection on controller (except jockey pump controller) Alarm signals on electric pump controller (except jockey pump) 1. pump running 2. pump failure 3. minimum water level(if required) 4. phase reversal 5. loss of phase 6. power suitable 7. lamp test (if required) 8. audible(can be switched off) and visible(can not be switched off) alarms 9. LRP Two 12 V batteries for diesel engine Battery chargers Additive alarm signals for diesel driven pumps 1. high motor temperature 2. low oil pressure 3. over speed 4. control is in automatic mode 5. charger lamp 6. failure of 1st battery 7. failure of 2nd battery 8. starting failure 9. failure of battery charger 10. engine running 11. lamp test button (optional) 12. audible(can be switched off) and visible(can not be switched off) alarms