Tecnofire
Tecnofire specializes in advanced automatic fire detection systems, offering high-technology solutions designed to ensure maximum safety and reliability across various environments.
All Products(7)

TFEVBD 2412EN
5" bidirectional aluminium sound projector. 10 W (100V) transformer. Selectable power 10-5-2.5W. Frequency response 130 Hz - 20000 Hz; Sound pressure: max SPL @1m: 101dB; max SPL @4m: 89dB; sensitivity 88dB; coverage angle: 130°. Aluminium installation support. Ceramic inlet and outlet connectors with thermal protection fuse. Material: aluminium; Protection rating: IP66; colour: Grey-RAL 7035. Dimensions: Depth: 184mm; Diameter: 146 mm. Weight 3.25 kg. EN 54 -24 Certification 1488-CPR-0641/W.

TFEVMCPTEN
Push-to-talk portable microphone certified EN54-16 for TFEVO6500 system. Push-to-talk portable microphone designed to be built-in or as an external accessory. Includes control and power board for integration into system priority audio input. Can be used both for public sound diffusion and voice evacuation applications compliant with EN54-16 standards.

TFEVOBMVF
Microphone voice alarm unit for Firemen, certified EN54-16. External remote control that incorporates an emergency push-to-talk microphone and provides direct access to the voice evacuation features of the system.
View Product
TSA1R
Addressable fire detection and extinguishing control panel. The characteristics listed refer to the TSA1 EXTENDED set-up. Equipped with a detection loop and an Extinguish Device Unit (EDU). The detection loop can handle up to 199 detectors, 99 modules and 9 TSM1 modules (peripheral EDU extinguishing channels). 2 RS485 serial buses for expansion device connection, up to 5 devices chosen from: repeater panels and/or communication devices. Serial buses also allow you to connect the unit in a network of Tecnofire control panels. The control panel manages 150 detection zones associated with 100 alarm plans, 8 time ranges. Advanced management with logic based on the application of formulas that dynamically relate the operating status of the system devices. 100 formulas. 100 Virtual detection zones. The control panel is equipped with 3 specialist signal outputs and 2 openly programmable signal outputs. The integrated EDU is equipped with: 3 conventional detection zone inputs, 7 controlled inputs for the management of the actuating and control devices, 2 controlled outputs for the management of the extinguishing valves, 2 controlled outputs for the management of the optical-acoustic alarm devices, 5 specialist signal outputs. Automatic or manual operating mode. Extinguishing cycle with 5 execution modes. Centralized or local management of 10 independent EDU, with local or centralized extinguishing cycle control, also in switching execution mode. User interface: 4.3"colour display, soft touch programming and management keyboard, 33 signal LED. Multifunctional acoustic warning buzzer. System RSC® management: programming, remote management and control. Customizable or permanent four-year calendar management. Event memory managed in FIFO logic capacity 8192 events. Modular 2.7A switching power supply unit. Battery capability: 2 x 12V-7Ah. ABS and steel casing. Surface mounting or via optional adapters in 19” rack casing. Protection rating IP3x. Available in the following colors: White, Grey, Red, Yellow. Dimensions (L x H x D) 440 x 345 x 146mm. Approved EN 54-2: 1997+ A1:2006 - EN 54-4: 1997+ A1:2002 + A2:2006 - EN 12094-1: 2003. Certification 0051-CPR–2816. System compatibility UNI EN 54-13:2020.

TSA1
Addressable fire detection and extinguishing control panel. The characteristics listed refer to the TSA1 EXTENDED set-up. Equipped with a detection loop and an Extinguish Device Unit (EDU). The detection loop can handle up to 199 detectors, 99 modules and 9 TSM1 modules (peripheral EDU extinguishing channels). 2 RS485 serial buses for expansion device connection, up to 5 devices chosen from: repeater panels and/or communication devices. Serial buses also allow you to connect the unit in a network of Tecnofire control panels. The control panel manages 150 detection zones associated with 100 alarm plans, 8 time ranges. Advanced management with logic based on the application of formulas that dynamically relate the operating status of the system devices. 100 formulas. 100 Virtual detection zones. The control panel is equipped with 3 specialist signal outputs and 2 openly programmable signal outputs. The integrated EDU is equipped with: 3 conventional detection zone inputs, 7 controlled inputs for the management of the actuating and control devices, 2 controlled outputs for the management of the extinguishing valves, 2 controlled outputs for the management of the optical-acoustic alarm devices, 5 specialist signal outputs. Automatic or manual operating mode. Extinguishing cycle with 5 execution modes. Centralized or local management of 10 independent EDU, with local or centralized extinguishing cycle control, also in switching execution mode. User interface: 4.3"colour display, soft touch programming and management keyboard, 33 signal LED. Multifunctional acoustic warning buzzer. System RSC® management: programming, remote management and control. Customizable or permanent four-year calendar management. Event memory managed in FIFO logic capacity 8192 events. Modular 2.7A switching power supply unit. Battery capability: 2 x 12V-7Ah. ABS and steel casing. Surface mounting or via optional adapters in 19” rack casing. Protection rating IP3x. Available in the following colors: White, Grey, Red, Yellow. Dimensions (L x H x D) 440 x 345 x 146mm. Approved EN 54-2: 1997+ A1:2006 - EN 54-4: 1997+ A1:2002 + A2:2006 - EN 12094-1: 2003. Certification 0051-CPR–2816. System compatibility UNI EN 54-13:2020.

TFA4-1192
Addressable fire detection control panel. With 4 detection loop lines. Each detection loop can manage: 199 detectors and 99 modules. 2 RS485 serial buses for expansion device connection, up to 16 devices chosen from: repeater panels and/or communication devices. The TFA4-1192 control panel can be part of a network of Tecnofire units. The control panel manages 300 fire detection or technical zones and 100 virtual detection zones. Automated management: 200 alarm plans, 32 time ranges, 400 formulas, server cyclic testing and customizable or permanent four-year calendar. Advanced management with logic determined by the application of formulas that dynamically relate the operating status of the system devices. The control panel is equipped with 4 specialist signal outputs and 6 openly programmable signal outputs. TLC Section: IP communication port, 4 communication channels: Local Server, Remote Server, Tecnoserver, Call back, 8 communicators for event notification, 2 IP address contacts for each communicator, 5 communication protocols, 15 transmittable event categories. Monitored system mode functions. User interface: 4.3” color display, programming and management keypad, 16 signal LED, speech synthesis and multifunctional acoustic signal buzzer. USB port. Serial printer management. System RSC® management: programming, remote management and control. Modular 5A switching power supply unit. Battery capability: 2 x 12V-12Ah. Aluminum and steel casing. Protection rating IP3x. Dimensions (L x H x D) 441 x 347 x 149mm. Approved EN 54-2: 1997+ A1:2006 - EN 54-4: 1997+ A1:2002 + A2:2006. Certification 0051-CPR–0388. System compatibility UNI EN 54-13:2020.

TFA1-298
Addressable fire detection control panel. Equipped with 1 detection loop. The loop can manage: 199 detectors and 99 modules. 1 RS485 serial bus for expansion device connection, up to 5 devices chosen from: repeater panels and/or communication devices. The control panel manages 150 fire detection or technical zones and 100 virtual detection zones. Automated management: 50 alarm plans, 8 time ranges, 100 formulas and customizable or permanent four-year calendar. Advanced management with logic based on the application of formulas that dynamically relate the operating status of the system devices. The control panel is equipped with 3 specialist signal outputs and 2 openly programmable signal outputs. Monitored system mode functions. User interface: 4.3” color display, programming and management keypad, 16 signal LED, speech synthesis and multifunctional acoustic signal buzzer. USB port. Serial printer management. System RSC® management: programming, remote management and control. Modular 2.7A switching power supply unit. Battery capability: 2 x 12V-7.2Ah. Aluminum and steel casing. Protection rating IP3x. Dimensions (L x H x D) 361 x 301 x 107mm. Approved EN 54-2: 1997+ A1:2006 - EN 54-4: 1997+ A1:2002 + A2:2006. Certificate 0051-CPR–0444. System compatibility UNI EN 54-13:2020.