Latest Products
100 items
Steel Wire Rope Ropetex PERFORM 6C
Rope construction: 6x36-IWRC, Compacted outer strands Marking: According to standard Standard: EN 12385-4
Steel wire rope veropro 8
Wire rope construction: veropro 8 is a 8-strand, non rotation-resistant rope with compacted outer strands and a rope core covered with a plastic layer. Features: Very high breaking strength. Very stabile rope construction with very good fatigue properties. A plastic layer between inner and outer strands prevents inner wear and protects the core from corrosion. Very high resistance against flattening and wear. Specially suitable for multilayer spooling (Lang Lay). ISO 4309 Rope Category No: Up to 42mm RCN.09, 43-48mm RCN.11, > 48mm RCN.13 Marking: According to standard Standard: EN 12385-4 Warning: veropro 8 may not be used with a swivel. Fill factor: 0.666 RCN: 09 Tolerance Ø: +2% to +4%

CW SOLO | Industrial Cable Gland
For all types of Steel & Aluminium Wire Armoured Cables Industrial Single Seal Cable Gland SOLO LSF Kit • Metal-to-metal armour clamping • Direct & remote installation • Controlled outer ‘load retention’ seal • Unique OSTG prevents overtightening • -60°C to +130°C • Deluge protection option • EMC tested • LUL (London Underground) approved

E1U | Industrial Cable Gland
Double Seal Industrial Cable Gland • Metal-to-metal armour clamping • Direct & remote installation • Permanently crimped, low impedance earth termination • Secure against self-loosening • Displacement type inner seal • Controlled outer ‘load retention’ seal • Unique OSTG prevents overtightening • Designed to prevent Coldflow • Deluge protection option • -60°C to +130°C • EMC tested


BUNDLES
Ritchie has been designing and supplying gas cylinder bundle frames to multinational industries since 1980 providing TPED and ISO BS EN 13769 certifications as appropriate. All testing of this equipment can be carried out by a third party on site in Forfar up to and including 64 cylinder frames. Bundles are provided with appropriate TPED and ISO BS EN 13769 certifications. Supplied to both European and International markets.


OFFSHORE CONTAINERS
Ritchie have been manufacturing offshore shipping containers for end users and hire companies for more than 20 years. A wide range of in house and bespoke designs of mini, half, three-quarter and full height designs for a variety of requirements is available. Full traceability and certification to DNVGL-ST-E271 and BS EN ISO 10855 is available together with a bespoke design and testing service for unique needs. Containers can be supplied with cargo nets or tarpaulins, anti-slip flooring and multiple tie- down points for securing cargo. Standard containers are 10’x8’ but are also available in 8’, 12’, 15’and 20’ lengths.


16 CYLINDER OFFSHORE GAS BUNDLE
Ritchie has supplied the offshore industry for more than 30 years supplying bundles that meet DNVGL-ST-E271 and BS EN ISO 10855 standards across the world. Standard bundle designs are available together with bespoke specified units and tube skids to meet variations in global and interface requirements. With all these designs we can supply manifolds, source cylinders and test them to your requirements.


64 CYLINDER MEGC OFFSHORE UNIT
Ritchie has supplied the offshore industry for more than 30 years supplying bundles that meet DNVGL-ST-E271 and BS EN ISO 10855 standards across the world. Standard bundle designs are available together with bespoke specified units and tube skids to meet variations in global and interface requirements. With all these designs we can supply manifolds, source cylinders and test them to your requirements.


16/6 CYLINDER OFFSHORE BASKET
Ritchie has supplied the offshore industry for more than 30 years supplying bundles that meet DNVGL-ST-E271 and BS EN ISO 10855 standards across the world. Standard bundle designs are available together with bespoke specified units and tube skids to meet variations in global and interface requirements. With all these designs we can supply manifolds, source cylinders and test them to your requirements.
L101H LED Beacon
The L101H is a compact, high output LED beacon ideal for all signalling applications including fire, status indication, security and process control. UL, cUL and ULC approved.
![B400RTH Rotating Beacon [Halogen Bulb]](https://www.e2s.com/system/1/product_assets/assets/000/000/132/132/de17bb2b7/medium/2-12-020_B400RTH-R.png)
B400RTH Rotating Beacon [Halogen Bulb]
The B400RTH rotating beacon features a 35/40W Halogen lamp providing 1,204 Candelas of light output. The parabolic reflecting mirror creates a focused beam of light maximising the visual effectiveness.

A100 Alarm Horn Sounder
The A100 is a compact, high output, 110dB(A) alarm sounder. CPR complaint, EN54-3 tested and UL/cUL and ULC approved. Featuring 64 alarm tone frequencies and 4 remotely activated stages/channels.

A112N Alarm Horn Sounder
The A112N is a high output 120dB(A) automatically synchronised alarm horn sounder. Globally approved for fire, marine and general signalling applications. Featuring 64 alarm tones and 4 remotely activated stages.


Large radius ESP sheaves

Freezstop Micro (FSM)
Freezstop Micro is an industrial grade, self-regulating heating tape that can be used for freeze protection or temperature maintenance of pipework and vessels. It is particularly suited to small diameter pipes and instrument tubing such as impulse or analyser lines. It can be cut-to-length on site to match exact piping lengths without any complicated design considerations. Freezstop Micro is approved for use in non-hazardous and hazardous areas to worldwide standards. Its self-regulating characteristics improve safety and reliability. Freezstop Micro will not overheat or burnout, even when overlapped upon itself. Its power output self-regulates in response to the pipe temperature.

FailSafe Ultimo (FSU / FSUw)
FailSafe Ultimo is an industrial grade self-regulating heating cable that can be used for freeze protection or temperature maintenance of pipework and vessels. It can be cut-to-length on site to match exact piping lengths without any complicated design considerations. FailSafe Ultimo is approved for use in non-hazardous, and hazardous areas to worldwide standards. Its self-regulating characteristics improve safety and reliability. FailSafe Ultimo will not overheat or burnout, even when overlapped upon itself. Its power output self-regulates in response to the pipe temperature.

SnoMelt (SM)
SnoMelt cables are industrial/commercial grade self-regulating heating cables that can be used for snow melting and ice prevention of surfaces such as concrete roads, ramps and paths. It may also be used on stairways, walkway gratings and loading docks. It can be cut-to-length on site to match exact lengths without any complicated design considerations. SnoMelt will not overheat or burnout, even when overlapped upon itself, although this is not recommended. Its power output self-regulates in response to the surface temperature. Its self-regulating characteristics reduce energy usage and lowers operating costs.

FailSafe Super (FSS)
FailSafe Super is an industrial grade self-regulating heating cable that can be used for freeze protection or temperature maintenance of pipework and vessels up to 225°C. It can be cut-to-length on site to match exact piping lengths without any complicated design considerations. FailSafe Super is approved for use in non-hazardous, and hazardous areas to worldwide standards. Its self-regulating characteristics improve safety and reliability. FailSafe Super will not overheat or burnout, even when overlapped upon itself. Its power output self-regulates in response to the pipe temperature.


D171 1IR+UV-SS Multi Spectrum Flame Detector
STANDARD FEATURES • Multi-Spectrum 1IR + UV design • Detects Hydrocarbon and Non-Hydrocarbon fires with the highest false alarm immunity • Standard outputs: Warning / Alarm / Fault / Auxiliary relays, 0-20mA and RS485 • 200 event history log & 6 FireGraphs® • Adjustable Time/Verification Delay up to 20 seconds • Automatic Self-Test checking electronic circuitry and Optical Path Integrity test with OptiRadar® • Standard 316 Stainless Steel enclosure • Test Mode for manual testing • Solar Blind • Heater Option to avoid condensation and icing • High False Alarm immunity to external non-fire sources • Manufactured in the USA with a 5-year warranty • RFI & EMC compliant • Meets SIL 2 requirements • NEMA 4 & 4X (IP66,67) and explosion-proof Stainless- Steel enclosure • FM/CFM/CSFM Approved


SPC-24 - Beam Detector
The Hochiki SPC-24 Projected Beam Smoke Detector consists of an emitter and receiver. The SPC-24 detector should be placed so that smoke generated by a fire will likely rise into the path of the beam. The receiver is constantly monitoring and measuring the intensity of the beam transmitted by the emitter. Should the smoke from a fire cause a decrease in the signal strength of a magnitude that exceeds the programmed obscuration setting, an alarm signal is generated. STANDARD FEATURES • Microprocessor based for reliability • Simple setup and alignment with signal strength LEDs • Provides 60 feet on center linear protection at a range of 32.8 feet to 328 feet • Automatic compensation for signal drift or dirty lens • Three field adjustable sensitivity settings • Form A alarm and Form B trouble contacts • Calibrated filters available to verify sensitivity (purchased separately) • Color-coded emitter (red) and receiver (green) labels for easy recognition • Adjustable to one of the three obscuration settings of 25%, 50% or 70% per span • Voltage and RF transient protection • External red LED when alarm condition is indicated


HCA-4D 4 Zone Conventional Panel with DACT, 6.5 AMP, 120VAC, Red
• UL864 9th Edition / NFPA Compliant • Fully programmable using simple menu options • Built-in two-line (16 Characters for each line) LCD display provides easy to read information • 15 Key control buttons for easy programming, reset and silencing. • Real time clock • Event History log (256 events) with Date/Time stamp, which can be viewed from LCD display • Compatible with wide range of detection devices • 4 Programmable Supervised NAC outputs • Switchable 120/240VAC 50/60 Hz Power supply • 5 Programmable output patterns for NAC circuits • Gentex Sync Protocol Built-in • Built-in Dialer for HCA-2D, HCA-4D and HCA-8D Only • Supports Releasing of Agents & Water on HCA-4 & HCA-8 models • Three programmable general purpose relays • Dedicated alarm and trouble relays • Built-in walk test feature • Supports up to two 12V, 18Ah Backup batteries • Supports one Remote Annunciator via RS-485


HCA-4 - 4 Zone Conventional Panel, 6.5 AMP, 120V, Red
The HCA series is available in a 2, 4, or 8 zone conventional panel design which is in accordance with UL 864 9th Edition Listing Detection and Fire Alarm Systems – Control and Indicating Equipment. STANDARD FEATURES • UL864 9th Edition / NFPA Compliant • Fully programmable using simple menu options • Built-in two-line (16 Characters for each line) LCD display provides easy to read information • 15 Key control buttons for easy programming, reset and silencing. • Real time clock • Event History log (256 events) with Date/Time stamp, which can be viewed from LCD display • Compatible with wide range of detection devices • 4 Programmable Supervised NAC outputs • Switchable 120/240VAC 50/60 Hz Power supply • 5 Programmable output patterns for NAC circuits • Gentex Sync Protocol Built-in • Built-in Dialer for HCA-2D, HCA-4D and HCA-8D Only • Supports Releasing of Agents & Water on HCA-4 & HCA-8 models • Three programmable general purpose relays • Dedicated alarm and trouble relays • Built-in walk test feature • Supports up to two 12V, 18Ah Backup batteries • Supports one Remote Annunciator via RS-485


ALO-V Multi-Criteria Smoke Detector and Duct Detector Head
The ALO-V (UL 268 7th edition listed) is a reliable, high quality Photoelectric Smoke Detector. It can be used in all open areas where Photoelectric Smoke Detectors are required. This detector is also suitable for monitoring smoke in HVAC ducts. The newly developed “multi-spectrum smoke categorization technology” detects smoldering and flaming fires fueled by traditional materials and polyurethane while reducing nuisance alarms. *NOTE-7th Edition Bases required The ASB7, ASBL7, SCI-B47, SCI-B67, YBN-NSA-47, and HSB-NSA-67 bases are compatible with the ALO-V. STANDARD FEATURES UL 268 7th Edition Listed Designed to resist unwanted alarms from cooking and other nuisance alarm sources Optical particulate identification Early fire smoke detection 360° view of detector status LED Programmable non-polling LED Vandal resistant security locking feature FLAT RESPONSE™ technology responds consistently to fire of all types, ensuring reliable detection of any fire emergency


HHLFR - Low Frequency Horn, 24VDC, Wall Mount, Red
The HHLF is a high quality, low profile, low frequency audible appliance that offers a dependable audible alarm with a low current draw. The HHLF is ideal for any occupancy that requires notification appliances. The HHLF horn offers a 520 Hz square wave, temporal 3 tone. A jumper selection is available for normal or loud decibel tone. A temporal 4 pattern is available when used with the Hochiki HTSM Synchronization Control Module. STANDARD FEATURES • Nominal voltage 24 VDC • Unit Dimensions: 6-1/8” (15.55 cm) high x 5-1/2” (13.97 cm) wide x 1-5/8” (4.13 cm) deep • Synchronize horn with Hochiki HTSM Synchroniza-tion Control Module • Prewire entire system, install mounting bracket, then install signals • Input terminals accept 12 to 18 AWG • Produces a 520Hz square wave, temporal 3 tone Jumper selection for normal or loud dBA • Temporal 4 pattern available when used with Hochiki HTSM Synchronization Module • Temporal 4 520Hz measured per ANSI/UL 2075 • Tamperproof re-entrant style grill and locking screw (optional use) • Faceplate available in red or off-white


HHLFR - Low Frequency Horn, 24VDC, Wall Mount, Red
The HHLF is a high quality, low profile, low frequency audible appliance that offers a dependable audible alarm with a low current draw. The HHLF is ideal for any occupancy that requires notification appliances. The HHLF horn offers a 520 Hz square wave, temporal 3 tone. A jumper selection is available for normal or loud decibel tone. A temporal 4 pattern is available when used with the Hochiki HTSM Synchronization Control Module. STANDARD FEATURES • Nominal voltage 24 VDC • Unit Dimensions: 6-1/8” (15.55 cm) high x 5-1/2” (13.97 cm) wide x 1-5/8” (4.13 cm) deep • Synchronize horn with Hochiki HTSM Synchroniza-tion Control Module • Prewire entire system, install mounting bracket, then install signals • Input terminals accept 12 to 18 AWG • Produces a 520Hz square wave, temporal 3 tone Jumper selection for normal or loud dBA • Temporal 4 pattern available when used with Hochiki HTSM Synchronization Module • Temporal 4 520Hz measured per ANSI/UL 2075 • Tamperproof re-entrant style grill and locking screw (optional use) • Faceplate available in red or off-white
Latest Manufacturers
20 items

Martek Marine

Metec Group
Metrol Technology
MICROPACK (Engineering) Ltd
Navitron Systems Ltd

R.B.Ross Steel Fabrications Ltd.
MME Group

Tyne Gangway (Structures) Ltd
Underwater Lights Limited
HellermannTyton

Hochiki America Corporation
Heat Trace Ltd
Hubbell Incorporated
Harper UK

Hades Oilfield Products
E2S Warning Signals

Durham Lifting

Ritchie Ltd

ORBINOX

Damper Technology Ltd
Latest Laboratories & Notified Bodies
5 items
Schmid & Partner Engineering AG
Stadtspital Zürich Waid, Zentrallabor
Suisselab AG Zollikofen
Steeltec AG
Suva, Bereich Chemie, Physik & Ergonomie, Prüfstelle für Akustik und Strahlenschutz
Latest Standards
50 items
Approval and test specification - Medical electrical equipment - General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
Methods of testing protective helmets Determination of load distribution
Chord Method of Evaluating Surface Microstructural Characteristics
Self-Sealing Breakaway Valves for Crash-Resistant Aircraft Fuel and Oil Systems
Requirements for connection to an air interface of a Telecommunications Network, Part 4: IMT-2000 and IMT-Advanced Customer Equipment
Personal eye protection, Part 6: Prescription eye protectors against low and medium impact
Low Power Data Communication System/Wireless LAN System
Requirements for connection to an air interface of a Telecommunications Network— Part 1: General
Eye and face protection - Sunglasses and fashion spectacles - Test methods
Techniques for Suspect/Counterfeit EEE Parts Detection by Electrical Test Methods
Information technology equipment - Immunity characteristics - Limits and methods of measurement
UWB (Ultra-WideBand) Radio Systems
Filters for eye protectors - Filters for protection against ultraviolet radiation
Techniques for Suspect/Counterfeit EEE Parts Detection by Radiological Test Methods
Corrigendum 1 - Amendment 1 - Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
Personal eye protection, Part 1: Eye and face protectors for occupational applications
Personal eye protection: Mesh eye and face protectors for occupational applications
Specified Low Power Radio Station 433MHz-Band Data Transmission Equipment for International Logistics
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
950MHz-Band RFID Equipment for Specified Low Power Radio Station
Safety of toys, Part 1: Safety aspects related to mechanical and physical properties
Requirements for connection to an air interface of a Telecommunications Network—Part 5: IMT-2020 Customer Equipment
Electromagnetic compatibility (EMC), Part 6.4: Generic standards - Emission standard for industrial environments (IEC 61000-6-4:2018 (ED 3.0) MOD)
Techniques for Suspect/Counterfeit EEE Parts Detection by External Visual Inspection, Remarking and Resurfacing, and Surface Texture Analysis Test Methods
SCREW THREADS - UNJ PROFILE, INCH
Eye and face protection - Sunglasses and fashion spectacles - Requirements
Benthic Macroinvertebrates: Sample Processing and Analysis
Digital Terrestrial Television Broadcasting for ISDB-T
Low Power Data Communication System/60 GHz-Band Wireless LAN for Very High Throughput Data Communications
Filters for eye protectors - Filters for protection against infra-red radiation
Plastics — Film and sheeting — Determination of thickness by mechanical scanning
Geotextiles and geotextile-related products - Determination of the tensile properties of geogrids by the single rib tensile test
Jetting resistance of drain and sewer pipes - Moving jet test method
Conformity assessment — Requirements for accreditation bodies accrediting conformity assessment bodies
Requirements and test methods for determination of the jetting resistance of components of drains and sewers
Inspection of Technical Cleanliness - Particulate Contamination of Functionally Relevant Automotive Components
Conformity assessment — Vocabulary and general principles
Testing of welded joints between panels and pipes made of thermoplastics – Tensile test
Vitrified clay pipes and fittings and pipe joints for drains and sewers - Part 3: Test methods
Information technology equipment - Immunity characteristics - Limits and methods of measurement
Methods of testing protective helmets, Method 5.2: Determination of strength of retention system — Dynamic strength
Methods of testing protective helmets - Method 7.1: Methods of test for retention systems - Dynamic strength
Electromagnetic compatibility (EMC), Part 6.2: Generic standards - Immunity standard for industrial environments (IEC 61000-6-2:2016 RLV (ED. 3.0) MOD)
Electromagnetic compatibility (EMC), Part 6.2: Generic standards - Immunity standard for industrial environments
Methods of testing protective helmets, Method 2: General requirements for the conditioning and preparation of test specimens and laboratory conditions
Testing of building facades
Methods of testing protective helmets Measurement of peak deflection
Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery - Safety - Part 4.6: Particular requirements for garden blowers, garden vacuums and garden blower/vacuums
