Bars = Total Score (manufacturers × adoption weight) • Line = # manufacturers • Click bars to search
Results for "EN 1751"
Products

Description BMVK: compact single-duct variable flow cistern galvanized sheet steel casing suitable for mounting via tie rods sealed shutter according to DIN 1946/4 - Class 4 EN 1751 Double density rock wool sound-absorbing material covered with black glass fibre, fire resistance M0; A1 according

Description Fire damper EI 120 S according to UNI EN 1366-2 classification UNI EN 13501-3 certificate no. 1438-CPR-0528 CE marking - VDI 6022 hygiene certificate Construction: 10/10 thick Z275 galvanized steel frame with male connection for direct insertion into the duct, offset calcium silica

Description Fire damper EI 120 S according to UNI EN 1366-2 classification UNI EN 13501-3 certificate no. 1438-CPR-0509 CE marking - VDI 6022 hygiene certificate Construction: 10/10 thick Z275 galvanized steel frame with flanges for duct connection, intermediate thermal cut, offset calcium sil

Description RPRT: variable flow rectangular regulator galvanized steel sheet casing aluminum shutter according to DIN 1946/4 and according to EN 1751 Class 4 dynamic ∆p probe for measuring and maintaining the required flow rate operating range from 20 to 1000 Pa flow regulation and control with

Description DLC-T: galvanized steel frame thickness. galvanized steel fin silicone perimeter seal applied to the fin control pin Ø 8 / 12 mm Bronze bushings for Ø 8 mm pins (-50°C / +200°C) Nylon bushings for Ø 12 mm pins (-20°C / +70°C) leakage class 4/B EN 1751 up to 2000 Pa DIN 1946/4

Frame in galvanized sheet metal 10/10 Z200 thickness 80 mm depth riveted, 30 mm flanges drilled Ø 5 mm on the corners “Double Skin“ fins in galvanized sheet metal, thickness 0.4+0.4 Z200, pitch 50 mm Internal gears in Nylon, temp. -20°C / +70°C Control pin Ø 8 mm L = 45 mm Tightness class 1 accordin

Galvanized steel construction with flanged duct connection. Volume flow controllers work with a smooth-running, asymmetrically angled plate, which guarantees a sensitive responding behavior even in case of low volume flows. Control plate is supported by two maintenance free PTFE bearings. Flow rate

Compact, robust and reliable: The Smoke PROtec smoke barrier n has only a few components. Nevertheless, it is a modern system for the protection of buildings and sections, which is also suitable for securing escape and rescue routes in areas of personal protection. The smoke barrier is made exclusiv

Astral Silencio pipes offer a reliable solution for demanding wastewater applications, combining excellent acoustics with durability. The pipe design allows for easy transitions from other systems without the need for special adapters. This top-quality piping system is designed to endure hot and col

Description Multi-blade fire damper EI 120 S according to UNI EN 1366-2 classification UNI EN 13501-3 certificate no. 2434-CPR-0283 CE marking - VDI 6022 hygiene certificate Construction: Z275 galvanized steel frame with silicate fiber interlayer, 30 mm flanges for duct connection, counter-mov

Fire damper EI 120 S according to UNI EN 1366-2 classification UNI EN 13501-3 certificate no. 1438-CPR-0529 CE marking - VDI 6022 hygiene certificate Construction: 10/10 thick Z275 galvanized steel frame with male connection for direct insertion into the duct, offset calcium silicate blade mount

Certified addressable sounder and visual alarm device. The SIREND sounder is an acoustic fire alarm notification device for buildings with EN 54-3, EN 54-17 certification and CE marking. The SIRENDL sounder is an acoustic and visual fire alarm notification device for buildings with EN 54-3, EN 54-

Large hotels, hospitals , schools,office buildings,supermarkets, commercial residential buildings, metro stations, railway stations, airports, kinds of transportation tunnels, petrochemical plants, thermal power plants, terminals, oil depots, large warehouses and industrial and mining enterprises, e

Mechanical smoke ventilation systems, often referred to as SHEVs, are crucial role in ensuring the safety of occupants and protecting buildings during a fire incident. These systems are designed to control the movement of smoke and heat, allowing for the safe evacuation of occupants and aiding firef

Bentones family of intermediate burners are well designed and robust burners aimed for an industrial process or heating of semi large commercial buildings. For many years these burners has been the backbone of Bentone and we have constantly modernized our burners to meet the new demands of modern re

The V2 parking system was designed to accommodate cars of any height. Its vertical adjustability allows our duplex parking system to be perfectly adapted to your needs. The V2 is ideal for parking garages, residential buildings, and offices. The V2 creates dependent parking spaces: before the platfo

Water tanks are crucial for tall structures that necessitate trustworthy, productive, and durable water storage alternatives. FTC Tanks is eager to bring you our innovative FRP Sectional Tank - a remedy that combines cutting-edge technology with top-notch functionality for an architectural period li
Standard
Standards in Results (10)
EN 12516-1
ASME B16.34
EN 12266-1
EN 175
EN 12516-2
API 598
EN 1451-1
ISO 5208
EN 1751
ANSI/ASME B16.34