Bars = Total Score (manufacturers × adoption weight) • Line = # manufacturers • Click bars to search
Results for "ANSI/UL 710"
Products

The Aquamatic Ecology Unit is designed specifically for the removal of smoke and grease particles from the air stream of commercial kitchen exhaust systems and to eliminate or reduce odor to an acceptable level if equipped with the optional odor control section. The AM-PCU is designed for use with a

Complete hood and filter wash system technology


AquaMatic's double island exhaust only ventilator, Model AM-NDI, is for use over cooking equipment in an island configuration, such as display cooking. The AM-NDI is an ETL Listed, Type I hood for the removal of equipment producing heat and grease laden effluent. The hood is rated for use over 400,

AquaMatic's low proximity exhaust only ventilator, Model AM-BD-2, sits closer to the cooking equipment than a traditional wall canopy style allowing for lower exhaust rates and smaller footprint. The AM-BD-2 is an ETL Listed, Type I hood for the removal of equipment producing heat and grease laden

UL Listed – Halton introduces a first of its kind, modular pollution control system that can be designed based on the projected grease loading and the critical nature of odor mitigation. You have the ability to determine the appropriate technology for the application. Whether an ELF unit with Extend

Duravents' Factory-Built, UL-Listed Prefab Grease Duct is designed for efficiency, safety, cost savings, and compliance. It provides a plug-and-play alternative to traditional welded steel duct systems.

The Contromatics unibody ball valves are offered in carbon steel and stainless steel with stainless steel trim standard on all configurations. Sizes range from 1/2"- 2", pressure rating of 2000 WOG with NPTF ends.

The Multiparker 710 offers space saving parking in a structure similar to a high-rack shelving system and is particularly suited to wider structures. Car transport is arranged crosswise. It is possible to provide the Multiparker 710 with a turntable unit which simultaneously during transport and lif

60-90 minute fire rated doors with temperature-rise tested to NFPA 252/UL 10B/UL 10C up to 10 ft. tall. Available with full-vision glazing, standard and narrow profiles, multiple hardware options and finishes including custom aluminum clad or stainless steel clad. See below for more information!

20-45 minute fire rated doors tested to NFPA 252/UL 10B/UL 10C up to 10 ft. tall. Available with full-vision glazing, standard and narrow profiles, multiple hardware options and finishes including custom aluminum clad and stainless steel clad. See below for more information!

2-piece Body Full Port Chrome-Plated Ball Virgin PTFE Seats Adjustable Packing Nut Blow-Out Proof Stem MSS-SP-110 500 psig (1-¼”, 2″) for UL use CSA B125.14 (¼” – 2”) CSA ½, 5 & 125 psi (½” – 2″) CSA ½ & 5 psi (2½” & 3″) 29 in-Hg rating for Vacuum Service UL approved (½” – 2”) FM approved (½” – 2″)

Trunnion mounted ball valves, construction to ASME B16.34 - API6D, 2/3 piece bolted body, split body, side entry, double block & bleed, flanged RF/RTJ to ANSI B16.5, face to face to ANSI B16.10, full/ reduced bore, ISO (5211) top work standardized for actuation, seat leakage rate to ISO 5208 Rate A,

EFS Multi-Blade fire damper is rated as a 3 hours fire damper for use in dynamic systems, per SI 1001 part 3 (UL 555). As a life safety fire damper, it has a failsafe design which enables the damper to automatically close upon the detection of heat and/or loss of power. The electric heat respons

EFS Multi-Blade fire damper is rated as a 3 hours fire damper for use in static systems, per SI 1001 part 3 (UL 555). As a life safety fire damper, it has a failsafe design which enables the damper to automatically close upon the detection of heat and/or loss of power. The electric heat responsi

EFS Multi-Blade fire damper is rated as a 1-1/2 hour fire damper for use in static systems, per SI 1001 part 3 (UL 555). As a life safety fire damper, it has a failsafe design which enables the damper to automatically close upon the detection of heat and/or loss of power. The electric heat respo

Reduces a higher inlet pressure to lower outlet pressure. Provides a consistent outlet pressure over a wide flow range. Pilot operated main valve is not subject to pressure fall-off. Outlet pressure is adjustable with a single screw. Can be maintained without removal from the pipeline. Flanged Ends

Y Strainer meets or exceeds the requirements of UL 321 Standard NPT Blow-Off Outlet on Body and Cover. ASTM A276, Type 304 Stainless Steel Screen. Excellent flow characteristics. Low pressure loss at high flow rates. Grooved Ends to AWWA C606 Standard. Fusion Bonded Epoxy Coated Interior and Exterio

Floating ball valves, construction to ASME B16.34 – ASME VIII Div.II, 2 piece bolted body, split body,side entry, flanged RF/RTJ to ANSI B16.5, face to face to ANSIB16.10, full/reduced bore, ISO (5211) top work standardized for actuation, metal seated (ball & seats with Tungsten or Chromium Carbides
Standard
Standards in Results (10)
ASME B16.34
API 6D
AWWA C515
ANSI/AWWA C550
AWWA C550
ANSI/AWWA C515
EN 593
ANSI/UL 710
API 607
API 6FA